- We recommend that you clean the device after
each time finished using.
- Clean the equipment regularly with a moist
cloth and some soft soap. Do not use cleaning
agents or solvents; these could attack the plastic
parts of the equipment. Ensure that no water can
seep into the device.
8.2 Air lter (B16)
In this connection, please also read the service
information.
- Clean the air filter at regular intervals, and
replace it if necessary.
- Remove fixing bolt on the air filter cover.
- Remove the filter elements (B16).
Important!
Do not use abrasive cleaning agents or petrol to
clean the elements.
- Clean the elements by tapping them on a flat
surface. In cases of stubborn dirt first clean with
soapy water, and then rinse with clear water and
air dry.
- Assemble in reverse order.
8.3. Spark plug (B4-8)
Check the spark plug (item 17) for dirt and grime
after 50 hours of operation and if necessary clean
with a copper wire brush. Thereafter service the
spark plug after every 50 hours of operation.
- Pull off the spark plug boot with a twist.
- Remove the spark plug with the supplied spark
plug wrench (15).
- Assemble in reverse order.
8.4 Changing the oil and checking the oil level
(B9-13)
The motor oil is best changed when the Engine is
at working temperature.
- Only use motor oil SAE - 15W40 / (<0
O
C) [SAE -
5W30].
8.4.1 Fill up Oil. (B13)
- Open the oil filler plug (9) by screw it off.
- Add exactly 0.35L engine oil with an oil filling
funnel.
Or refer to content in 8.4.2.
- Screw the Oil filler plug back.
8.4.2 Checking Oil level. (B12)
- Place the generator on a slightly inclined surface
so that the dip stick is at proper position.
- Screw off the Oil Filler plug and wipe off any oil
on the dip stick.
- Put the oil dip stick back without screw into the
Oil filler.
Important!
Do not screw the dipstick in to check the oil level;
simply insert it up to the thread.
- Check the dip stick; make sure the oil level is
between “H” and “L mark.
8.4.3 Let out used Oil (B17)
- Open the oil filler screw (9).
- Drain the used oil into a suitable receptacle by
tilting the generator.
8.4.4 Changing Engine Oil
- changing engine oil refers to the content in 8.4.3
and 8.4.1.
8.5 Oil shortage cut-out
This generator has a Low Oil level Protection
system.