E6 – Runaway Belt Error
OVERVIEW
If the actual belt speed is greater than the target speed by a limit and increasing
then an E6 error is called. E6 errors flag errors that will result in the belt “running
away” or not responding to input.
Error 6
Before cycling power inspect
the motor controller for error
conditions
Motor Controller Error
Record error code
information from motor
controller
Record console error code
parameters recorded with
current error code
Inspect all electrical connections,
ensure that all connections are
properly made and there are no
shorts to adjacent conductors
Step 2 :
1.Remove Power!!! Carefully check all connections, interface board and the
Reliance Motor controller setting to ensure all settings are correct.
2.Run the system at maximum speed to ensure no additional failures occur.
Speed feedback
issue
Speed control
issue
Speed Feedback Issues – See speed feedback issue trouble shooting guide in
the CORRECTIVE ACTION PROCEDURES – Speed Issues section of this
document.
Speed Control Issues – See speed control issue trouble shooting guide in the
CORRECTIVE ACTION PROCEDURES – Speed Issues section of this
document.
Step 1 :