SERVICE MANUAL
MAINTENANCE AND TROUBLESHOOTING
GUIDE
FOR MATSUI DMZ DRYERS
Phone (847)290-9680 Fax (847) 290-9685 www.matsuiamerica.com
ITEM: PAGE:
INTRODUCTION 2
NOMENCLATURE 2-3
DAILY MAINTENANCE SCHEDULE 4
MONTHLY MAINTENANCE SCHEDULE 4
6 MONTH MAINTENANCE SCHEDULE 4
MAINTENANCE DESCRIPTIONS AND DIRECTIONS 5-12
ALARMS 13-18
TROUBLESHOOTING 19-22
FREQUENTLY ASKED SERVICE QUESTIONS 23-25
COMMON SPARE PARTS 26

Questions and Answers

  • K
    Kelly CunninghamAug 13, 2025
    How to fix a Matsui DMZ-170 when the blower does not turn on?
    • B
      benjamin37Aug 14, 2025
      If the blower in your Matsui Dryer doesn't turn on, there are several things you can check. First, ensure the disconnect or breaker is turned on. Then, inspect the fuse and replace it if necessary, and verify all power connections are secure. Also, make sure that no value is entered in the 'TIMER' mode. Check the contactor coil for 100V; if present, replace the magnetic contactor. If there's no voltage, it's best to contact Matsui Service. Try resetting the overload. Follow the Maintenance Instructions to check the contactor; if it's fine, replace the overload relay. Finally, check for any loose or shorted wires.
  • T
    Theresa WoodAug 17, 2025
    What to do if the drying temperature highest or lowest alarm in Matsui Dryer?
    • A
      Amy MasseyAug 17, 2025
      If the drying temperature in your Matsui Dryer is alarming high or low, first allow the dryer to complete its warm-up cycle and let the temperature stabilize. You should also install new filters. Check and correct any voltage problems. Address the issue by replacing the contactor or repairing the blower. Finally, replace or adjust the thermocouple.
  • S
    Samantha BrownAug 21, 2025
    Why does the blower overload relay trip in my Matsui Dryer?
    • K
      Kimberly FosterAug 21, 2025
      If the blower overload relay trips in your Matsui Dryer, first check the corresponding blower for the proper amp setting and reset it. Also, check for any obstructions inside the blower and clear them. If the problem persists, replace the contactor and reset the overload relay.
  • L
    Laura MartinAug 25, 2025
    What to do if the moisture content of resin does not go down in Matsui DMZ-170 Dryer?
    • J
      Jason BarrettAug 25, 2025
      If the moisture content of the resin in your Matsui Dryer isn't decreasing, increase the temperature to a minimum of 130°F (55° C). Install new filters. Ensure the strainer is clean and the water is turned on. Replace hoses with the proper type. Finally, inspect and replace components following the directions in the Maintenance section.
  • D
    dcummingsAug 28, 2025
    Why drying temperature does not go up or down in Matsui DMZ-170?
    • A
      Andrew RileyAug 28, 2025
      If the drying temperature in your Matsui Dryer isn't changing, check the voltage at the coil of the contactor and the output of the controller for proper operation. Replace the contactor or service the controller as needed. Inspect the thermocouple wiring and replace the thermocouple if defective. Also, replace hoses with the proper type.
  • C
    Carlos ObrienSep 1, 2025
    Why drying temperature changes rapidly in Matsui DMZ-170?
    • R
      rachelcortezSep 1, 2025
      If the drying temperature in your Matsui Dryer changes rapidly, install new filters. Replace or adjust the thermocouple. Also, correct the thermocouple polarity.
  • J
    Joshua GarciaSep 5, 2025
    How to increase blower airflow in Matsui DMZ-170?
    • R
      Robert HowardSep 5, 2025
      To address low blower airflow in your Matsui Dryer, start by installing new filters. Replace any incorrect hoses with the proper type. Also, remove the intake and exhaust ports from the blower and clear any plugs or clogs.
  • R
    ryan41Sep 9, 2025
    What to do if PV or SV indicator does not display on Matsui DMZ-170 Dryer?
    • K
      kellymunozSep 9, 2025
      If the PV or SV indicator on your Matsui Dryer isn't displaying, first, turn on the power supply. If that doesn't work, check the glass fuse (F-1) inside the control panel and replace it if necessary.

Summary

Nomenclature and Component Identification

Daily Maintenance Schedule

6 Month Maintenance Schedule

Detailed Maintenance Descriptions and Directions

Contactor Resistance Checks

Explains how to check magnetic heater contactors using a multimeter.

Heater Resistance Checks

How to check regeneration and process heater resistance.

Desiccant Rotor Inspection

Details checking the desiccant rotor for proper operation and adjustment.

Alarms and Controller Information

Reverse and Overload Alarms

Troubleshooting for Reverse and Overload alarms, common to both controllers.

Filter, Sensor, and Temperature Alarms

Troubleshooting for Filter, Sensor, H'EST (Highest), and L'EST (Lowest) alarms.

Overheat and Heater Alarms

Troubleshooting for Overheat, Heater (MR-2200), Material Low, and Dew Point alarms.

Troubleshooting Common Issues

Safety Warnings

Critical safety warnings regarding electrical work and dryer operation.

Matsui DMZ-170 Specifications

General IconGeneral
BrandMatsui
ModelDMZ-170
CategoryDryer
LanguageEnglish

Related product manuals