9.02
Troubleshooting
PROBLEM
C. Oil
Excessive oil consumption; the
oil the level lowers too quickly;
clogged; oil is detected inside the
system.
D. Temperature
The compressor stops due to its own
over-heating.
The compressor stops due to the
over-heating of the motor.
SOLUTION
Replace lters and verify the causes of
the clogging.
(see Section 7)
Replace the lters and verify the causes
of clogging.
(see section 7)
Verify the setting and re-set to the value
foreseen for the machine.
(see Section 7)
Verify the environmental conditions and
the condition of the ltering panel.
(see Sections 3 and 7)
CAUSE
The oil return valve lters are clogged.
The radiator or the cooling air lter are
Dirty the ambient temperature is too
hight for compressor operation.
Excessive working pressure.
The motor cooling is not sufcient;
There is not enough air or it is too hot.
TI008G0001