- Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair
requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent
in the use of flammable refrigerants.
5. INSTALLATION REGULATIONS
- The unit must be installed by qualified personal and in compliance with the national legislation in force in the country
of destination. The company will not assume any liability for damage if these instructions are not respected.
- Before begining any work read the manual carefully and perform the related safety checks to avoid any possibility of
danger. All the staff involved must have thorough knowledge of the operations and any dangers that may arise at the
moment in which the installation operations are carried out.
6. INSTALLATION WARNINGS
• The employed refrigerant gas is R32.
• Be sure only trained and qualified service personnel to install, repair or service the equipment. Improper installation,
repair, and maintenance may result in electric shocks, short-circuit, leaks, fire or other damage to the equipment.To
guarantee the unit operates correctly, and the choice of location for the installation must meet the following criteria:
• The outdoor unit must be installed so as to ensure that air discharged from the unit itself is not recirculated and there
is sufficient space around the machine for operations and maintenance.
• The installation site must be well-ventilated so that the outdoor unit can take in and discharge sufficient quantities of
air. Ensure that there are no obstacles near the outdoor unit’s air inlets or outlets. Remove any obstacles which may
be blocking the intake or discharge of air.
• The site of the installation must be sufficiently solid to bear the weight of the outdoor unit, and it must also be able to
absorb any vibrations and insulate against noise. Ensure that the air and noise coming from the unit do not disturb
your neighbours.
• The site of the installation must ensure that the outdoor unit cannot become buried in snow and it is not subject to
the effects of fumes from fuel and oils.
• Avoid direct exposure of the unit to solar radiation: it is recommended to install protection.
• The installation site must guarantee drainage of rainwater and water produced during the defrosting cycle.
• The site of installation must be positioned so that the discharge air outlet is not exposed to strong winds and the air
discharged must be free to disperse into the atmosphere.
• To avoid disturbances, the power cables of the units should be placed at a distance of over a meter away from the
electronic equipment such as televisions, radio, etc. (in the case of cables with a large load, the distance of 1 meter
may not be sufficient).
• Do not install the unit in a place where flammable gas could leak or where flammable, explosive, poisonous materials
and other hazardous substances are stored. Do not use naked flames near the units. Risk of fire or explosion. Install
the unit in a place with minimal amounts of dust, vapour and moisture in the air.
• Do not, under any circumstance, put your finger or any objects into the unit. This may cause injuries due to the high
speed of the internal fans.
• Periodically check that the installation conditions of the unit have not been altered: have the system checked by
“Personnel with specific technical skills”.
• Do not modify the units! Do not attempt to repair the unit alone, this is extremely dangerous! Improper interventions
may cause electric shocks, water leaks, fires, etc.
Contact our After-Sales Service in your area. Interventions may only be carried out by “Personnel with specific
technical skills”.
• Ensure that the power supply and the installed output are adequately scaled to supply the air conditioner correctly.
• Before operating the air conditioner, ensure that the electric cables, condensate discharge pipes and refrigerant
connections have been correctly installed to avoid the risk of water leaks, refrigerant gas leaks and electric shocks.