EasyManua.ls Logo

Maximum Controls MAX MEGATRON 1400HP - Entrapment Protection

Maximum Controls MAX MEGATRON 1400HP
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
Wireless
Module
Beam Height:
21” Normal
27.5” Max.
Beam: 5” or LESS from CLOSED gate.
CLOSING direction Photocell
OPENING direction Photocell,
Install just above gate operator.
Entrapment
Area
Entrapment Area
Gate Open
Gate Open
Top View
Side View
Dual Gate Operators NOTE: Run EACH entrapment
protection sensor to each corresponding GATE
OPERATOR’S MC-200 motor controller. See page 9.
installation
entrapment protection
Entrapment Protection
10K Sensing Edge,
Install along entire
edge of gate.
Conduit
The hinge area may need protection
against entrapment. MAX 10K mini
sensing edge works well in this area.
(OPEN/CLOSE direction, MC-200
Edge 2 or Photo Cell input)
Gate Closed
Normally CLOSED (N.C.)
OPENING direction Photocell
OPEN/CLOSE Sensing Edge on Bottom of Gate: If
the bottom of gate is 6” or higher above the ground,
then a 10K sensing edge should be installed.
6” or More
Bottom of Gate
See pages 17-18 for wiring
instructions.
IMPORTANT: Photocells
MUST be Monitored
Normally Closed Type.
IMPORTANT: Sensing edges MUST be Monitored 10K Normally
Closed Type and a GEM-104 module MUST be installed.
Closed Gate
Max 10K Mini Sensing Edge (N.C.)
Hinge AreaEnd of Gate Options
IMPORTANT:
Photocells MUST
be in alignment
or fault will occur.
IMPORTANT: Photocells MUST
be in alignment or fault will occur.
Install photocells and/or sensing edges to help protect against entrapment during cycling of the gate (entrapment protection).
ONE entrapment protection sensor MUST be installed and connected to “Edge 1 CLOSING direction” on MC-200 motor
controller or operator will NOT function. Entrapment protection sensors MUST be MONITORED and NORMALLY CLOSED (N.C.).
CLOSING direction photocell to
MC-200 EDGE 1 input, Monitored.
Normally CLOSED (N.C.)
OPENING/CLOSING
Two Sided 10K Sensing Edge
to Edge 2 or Photo Cell input
MC-200 Edge 2 or Photo Cell input
CLOSING ONLY
One Sided
10K Sensing Edge
MC-200 Edge 1 input
Cl
osed Gate
Closed Gate
OPENING/CLOSING or
Closing ONLY 10K (N.C.)
Sensing Edge
WIRELESS NOTE: Refer to the instruction sheet that
comes with the wireless module for wiring and
mounting instructions when using wireless option.

Table of Contents