CARTRIDGE FILTER
To remove filter for cleaning again, hold
lid assembly with one hand and turn
retainer counter-clockwise.
Clean filter by tapping it on inside of
trash can. Clean filter by rinsing from
the inside.
4
6
Slide cartridge filter off filter cage.
When wet (to prevent mould and/or mildew build-up), the cartridge filter should
be moved and allowed to air dry for a 24-hour period before being re-installed
back onto the filter cage.
5
7
WARNING!
Always disconnect the plug from the power outlet before
removing the power head from the collection tank.
Problem Possible Causes Corrective Action
Wet/Dry Vacuum will not
operate.
No power supply. Check power supply: cord,
breakers, fuses.
Faulty power cord. Check the power cord
and repair or replace as
necessary.
Tank is full of liquid. Empty tank.
Motor cover emits dust. The cartridge filter is
missing or damaged.
Attach or replace the
cartridge filter.
Reduced efficiency and
motor/speed vibration.
Blockage in the nozzle,
hose or the tank inlet.
Check the nozzle, the hose
and the tank or filter inlet
for blockage.
Filter may be blocked by
fine dust.
Remove the filter, wash and
clean it. Do not reuse until
it is completely dry. Use a
new filter if necessary.