Flameout
E08
Fault Code Cause of Failure Solutions
1. Check if there is insufficient oil, low-temperature solidification of oil, blockage of oil passage, or oil pump stuck;
2. Check if the inlet and exhaust air ducts are unobstructed;
3. Check if the temperature sensor on the casing is in full contact with the casing, and whether the pressure
spring is strong.
Unsuccessful start up
E09
1. The casing temperature is too high, and the casing cannot be blown cold after 3 minutes of starting.
2. There is a lot of white smoke in the exhaust gas.
2.1 Check if the filter next to the ignition plug is clean, clean or replace if it is dirty;
2.2 Check if the oil pump has strong fuel injection;
2.3 Check if the ignition plug is aging.
3. There is a small amount of white smoke or no smoke in the exhaust gas.
3.1 Check if there is insufficient oil, frozen or blocked oil passage;
3.2 Check if the oil pump is stuck or damaged and unable to pump oil;
3.3 Check if the combustion intake and exhaust passages are unobstructed;
3.4 Check if the glow plug is damaged;
3.5 Check if the gap between the internal wind wheel is too large.
4. The ignition is normal but the ignition failure fault is still reported.
Check if the temperature sensor on the casing is in full contact with the casing, whether the pressure
spring is strong, and whether the sensor is normal.
1.Check if the temperature sensor connection line and connector are damaged or loose, and confire the
sensor is damaged or not.
Sensor fauilure
PARKING AIR HEATER
31
PRECAUTIONS
&
MAINTENANCE
07
PARKING AIR HEATER
32
The heater must be checked carefully before use, ensuring
that there are no leaks and that all connections are in safe
conditions. If dense smoke, fuel smells or irregular noise
become apparent, the heater must be shut down and the
fuse removed. The heater must only be put back into use
after repair by a qualified professional.
8.1 Check Before Use