2 -General Characteristic Parameters
No. Characteristics
Test
conditions
Min. Nom. Max. Unit
1 Operating Voltage 200 220 240 VAC
2 Input Power 100% Output/MA1-35 3
kW
100% Output/MA1-45 4.8
100% Output/MA1-65 6
3
Operating Ambient
Temperature
0 40
℃
4
Operating Ambient
Relative Humidity
10 85
%
5 Laser cooling method Phase change heat dissipation
6 Cooling method of tip Nitrogen and argon cooling
7 Storage Temperature -10 60
℃
8 Dimensions
MA1-35 588*265*512
mmMA1-45
667*276*542
MA1-65
9 Weight
MA1-35
29
±
3
kgMA1-45
38
±
3
MA1-65
39
±
3