16
Chapter 4 Specication
2-General Characteristic Parameters
NO. Characteristics Test Conditions Min. Typical Max. Unit
1
Operating
Environment Tem.
10 35
2
Storage
Temperature
-10 60
3 Cooling Air-cooling
4 Warm Up Time
-Operate 1 min
-Stable 10 min
5
Operating
Environment humidity
10 95 %
6 Dimensions
MFP-100W 557*483*177 mm
MFP-200W
MFP-300W
586*420*142.5 mm
7 Weight
MFP-100W 23 kg
MFP-200W
MFP-300W
21 kg
8 Power Supply 220 VAC
9
Power
Consumption
MFP-100W 600 W
MFP-200W 900 W
MFP-300W 1300 W
13 Beam Diameter 1/e2 5 8 mm
14 Beam Ellipticity 90 %
15
Delivery Cable
Length
5 M
16 Laser startup Time
Pout=Pnom,
0%~90%
200 us
17
Laser Shutdown
Time
Pout=Pnom,
100%~10%
150 us
* For reference only. Other beam diameter available by order.