XStream™OEMRFModuleProductManualv5.x00[2006.02.24]
CD (DO3 Configuration) Command
AT Command: ATCD
Binary Command: 0x28 (40 decimal)
Parameter Range: 0 – 4
Parameter Configuration
0 RX LED
1 Default high
2 Default low
3 (reserved)
4
Assert only when packet
addressed to module sent
Default Parameter Value: 0
Number of bytes returned: 1
Minimum Firmware Version Required: 4.2B
<Serial Interfacing> CD Command is used to
redefine the behavior of the DO3 (Data Output
3)/RX LED line.
CE (Connection Inactivity Timeout) Command
AT Command: ATCE
Binary Command: 0x34 (52 decimal)
<Networking & Security> Set/Read the duration
of inactivity that will cause a break in a
connection between modules. The base module
will disconnect when no payload has been
transferred for the time specified by the CE
parameter.
Parameter Range: 0 – 0xFFFF
[x 10 milliseconds]
Default Parameter Value: 0x64 (1d second)
Number of bytes returned: 2
Related Commands: CB ( Connection Duration
Timeout), DC (Disconnect), MD (RF Mode)
Minimum Firmware Version Required: 4.30
CF (Connection Failure Count) Command
AT Command: ATCF
Binary Command: 0x35 (53 decimal)
Parameter Range: 0 – 0xFFFF
Default Parameter Value: 0
Number of bytes returned: 2
Minimum Firmware Version Required: 4.30
<Diagnostics> Set/Read the number of times the
base module expired retries attempting to send a
Connection Grant Packet. Set to zero to clear the
register.
CL (Last Connection Address) Command
AT Command: ATCL
Binary Command: 0x39 (57 decimal)
Parameter Range: 0 – 0xFFFF [read-only]
Number of bytes returned: 2
Minimum Firmware Version Required: 4.30
<Diagnostics/Networking & Security> Read the
address of the remote module that last
connected to the base module. A remote module
will return its DT (Destination Address)
parameter.
CM (Connection Message) Command
AT Command: ATCM
Binary Command: 0x38 (56 decimal)
Parameter Range: 0 – 1
Parameter Configuration
0 enable
1 disable
Default Parameter Value: 0
Number of bytes returned: 1
Minimum Firmware Version Required: 4.30
<Networking & Security> Select whether base
sends connect messages to the host when a
connection is established. When enabled, a
“CONNECTXXXX” string is sent to the host of the
base module. “XXXX” is the MY (Source Address)
of the connected remote module.
©2006MaxStream,Inc.ConfidentialandProprietary 22