EasyManua.ls Logo

MaxStream XStream X09-001 Series - Antennas

MaxStream XStream X09-001 Series
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
XStream™OEMRFModuleProductManualv5.x00[2006.02.24]
Antennas
[Refer to Appendix A for a list of FCC-Approved Antennas]
Fa s link range:
e (interference)
ctors that determine wireles
Ambient RF nois
Line-of-sight obstructions
Transmit power
Receive sensitivity
Antenna configuration
XStream Antenna Connector Options
To comply with the FCC rules and obtain a “modular” certification, it is required that XStream
to ensure the modules are used only with
. The XStream Modules have two connector options:
RPSMA
MMCX
ternatively, the XStream Module can be order with an attached wire antenna.
PSMA
Modules utilize a “non standard” connector. This is
approved antennas
Al
R
The
re
©2006MaxStream,Inc.ConfidentialandProprietary 56
Reverse Polarity SMA (RPSMA) connector uses the same body as a
gular SMA connector. In order to be a “non standard” connector, the
as a male center conductor.
MCX
gender of the center conductor is changed. The female RPSMA actually
h
M
The Micro-Miniature Connector (MMCX) is a good solution for
high volume, price-sensitive applications. The small size and
snap on connection make it suitable for attaching an external
An
mounted antenna to a module inside an enclosure.
tenna Cables
RF cables are typically used to connect a radio installed in a cabinet to an antenna mounte
externally. As a general rule, it is best to keep the RF cable as short as possible. All
d
cables
loss per 100 ft. MaxStream provides LMR-
95 rated cables. Common cables and dB losses are included in this table:
ableB04. PotentialSignalStrengthLossduetoAntennaCableLength
promote signal loss which is usually measured in dB
1
T
Cable Loss at 900 MHz per 100’ Loss at 2.4 GHz per 100’
Diameter
Type (loss per 100m) (loss per 100m)
RG-58 14.5 dB (47.4 dB) 25.3 dB (83.2 dB) 0.20” (4.95 mm)
RG-174 25.9 dB (85.0 dB) 44.4 dB (145.8 dB) 0.10” (2.54 mm)
RG-316 24.7 dB (81.0 dB) 42.4 dB (139.0 dB) 0.10” (2.59 mm)
LMR-195 11.1 dB (36.5 dB) 19.0 dB (62.4 dB) 0.20” (4.95 mm)
LMR-240 7.6 dB (24.8 dB) 12.9 dB (42.4 dB) 0.24“ (6.10 mm)
LMR-600 2.5 dB (8.2 dB) 4.4 dB (14.5 dB) 0.59” (15.0 mm)
Downloaded from Elcodis.com electronic components distributor

Related product manuals