This manual describes the function, operation and maintenance of the Maxtec Model MAXO
2
ME
oxygen monitor. The MaxO
2
ME utilizes the Maxtec MAX-550E oxygen sensor and is engineered for
fast response, maximum reliability and stable performance. The MaxO
2
ME is designed primarily
for continuous monitoring of oxygen levels delivered by medical oxygen delivery equipment and
respiratory care systems. Adjustable high and low level alarm set points make the MaxO
2
ME ideal
for use in neonatal, anesthesia and respiratory care.
CLASSIFICATION
Protection Class: ...................................................... II, Type B
Ingress Protection Rating: ...................................................IPX2
Mode of Operation: ...................................................Continuous
Sterilization: ......................................................See section 6.0
Safety of application in the presence of a flammable anesthetic mixture:.........See section 8.1
Power specification: ................................7.5V(MAX) 1.9W.250mA(MAX)
CAUTION: Federal law restricts this device to sale by or on the order of a medical professional.
Product Disposal Instructions:
The sensor, batteries, and circuit board are not suitable for regular trash disposal. Return
sensor to Maxtec for proper disposal or dispose according to local guidelines. Follow local
guidelines for disposal of other components.
WARRANTY
The MaxO
2
ME Monitor is designed for medical oxygen delivery equipment and systems. Under
normal operating conditions, Maxtec warrants the MaxO
2
ME Monitor to be free from defects of
workmanship or materials for a period of two (2) years from the date of receipt from Maxtec, provided
that the unit is properly operated and maintained in accordance with Maxtec’s operating instructions.
Based on Maxtec’s product evaluation, Maxtec's sole obligation under the foregoing warranty is limited
to making replacements, repairs, or issuing credit for equipment found to be defective. This warranty
extends only to the buyer purchasing the equipment directly from Maxtec or through Maxtec's
designated distributors and agents as new equipment. Maxtec warrants the MAX-550E oxygen sensor
in the MaxO
2
ME
Monitor to be free from defects in material and workmanship for a period of two
(2) years from Maxtec's date of shipment in a MaxO
2
ME
unit. Should a sensor fail prematurely, the
replacement sensor is warranted for the remainder of the original sensor warranty period. Routine
maintenance items, such as batteries, are excluded from warranty. Maxtec and any other subsidiaries
shall not be liable to the purchaser or other persons for incidental or consequential damages or
equipment that has been subject to abuse, misuse, mis-application, alteration, negligence or
accident. THESE WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED
OR IMPLIED, INCLUDING WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
9700630
Conforms to AAMI STD ES60601-1, ISO STD 80601-2-55,
IEC STDS 60601-1-6, 60601-1-8 & 62366
Certified to CSA STD C22.2 No. 60601-1
!

Questions and Answers: