14
Cubes are
too small
The ambient
temperature
The ambient
temperature is too
high.
Adjust the ambient
temperature.
Electronic
controller
The setting
temperature is high.
See the service manual "adjust
the size of ice cubes"
Refrigerant
Refrigerant leaks
Recharge.
Cubes are
too big
Electronic
controller
The setting
temperature of
Electronic controller
is low.
See the service manual "adjust
the size of ice cubes"
Sensor
Temperature sensor of
the evaporator
damages
Replace the sensor of
temperature.
The ambient
and water
temperature
The ambient
temperature and water
temperature is too low.
Adjust the temperature.
The cubes
are
partially
formed--h
ave ragged
sides
Water quality
The water quality is
poor
Using a water-soften / filter
apparatus installed in front of
the water inlet valve.
Evaporator
Ice machine is dirty
Clean and sanitize the ice
machine
Water
distribution
tube
The water distribution
tube blocks partially
Clean the water distribution
tube
The room
temperature
The room temperature
is out the stated range,
the water pump stop
Make the temperature returns
within the stated range.
The ice
cubes
shape
deformity
Filter
Water filtration
element needs to be
changed
Replace the filter
Water trough
Water trough level is
too low
Adjust the water floater
Cubes are
partially
formeda
re white at
the bottom
The room
temperature
The room temperature
is out the stated range,
the water pump stop
automatically.
Make the temperature returns
within the stated range.
Water trough
Water trough level is
too low
Adjust the water floater
4.Other problems