Application
ROBA
®
-switch fast acting rectifier units are used to connect DC
units to alternating voltage supplies, for example electromagnetic
brakes and clutches (ROBA-stop
®
, ROBA
®
-quick, ROBATIC
®
),
electromagnets, electrovalves, etc.
Fast acting rectifier ROBA
®
-switch 017.110.2
Consumer operation with overexcitation or power reduction
Integrated automatic DC-side disconnection
(shorter connection time)
Input voltage: 100 - 500 VAC
• Max. output current I
RMS
: 1,5 A
• UL-approved
The ROBA
®
-switch units with integrated automatic
DC-side disconnection are not suitable for use as safety
disconnections!
Function
The ROBA
®
-switch units are used for operation at an input
voltage of between 100 and 500 VAC, depending on the size. They
can switch automatically internally from bridge rectification out-
put voltage to half-wave rectification output voltage. The bridge
rectification time can be modified from 0,05 to 2 seconds by
exchanging the external resistor (R
ext
).
The ROBA
®
-switch units also have an integrated automatic DC-
side disconnection. In contrast to the conventional DC-side
disconnection, no further protective measures or external
components are necessary. The DC-side disconnection is stand-
ard-activated (terminals 3 and 4 are not wired), resulting in short
electromagnetic consumer switching times.
The integrated automatic DC-side disconnection is deactivated
by fitting a bridge between the terminals 3 and 4. The coil is
deenergised via the free wheeling diode. This has the advantages of
softer braking and a lower switching noise. However, the switching
times increase (taking approx. 6 - 10 times longer).
Electrical Connection (Terminals)
1 + 2 Input voltage (fitted protective varistor)
3 + 4 Switching between DC- and AC-side disconnection
5 + 6 Output voltage (fitted protective varistor)
7 + 8 R
ext
for bridge rectifier timing adjustment
Technical Data
Input voltage see Table 1
Output voltage see Table 1
Protection IP65 components, IP20 terminals
IP10 R
ext
Terminal nom. cross-section 1,5 mm
2
, (AWG 22-14)
Ambient temperature -25 °C up to +70 °C
Storage temperature -40 °C up to +105 °C
Dimensions (mm)
ROBA
®
-switch Sizes, Table 1
Size
10 20
Input voltage
VAC ± 10 %
100..
..250
200..
..500
Output voltage
VDC, U
bridge
90..
..225
180..
..450
Output voltage
VDC, U
half-wave
45..
..113
90..
..225
Output current I
RMS
at ≤ 45 °C, (A)
1,5 1,5
Output current I
RMS
at max. 70 °C, (A)
0,75 0,75
Conformity
markings
Order Number
__ / 0 1 7 . 1 1 0 . 2
Size
10
20
Accessories:
Mounting bracket set for
35 mm rail acc. to EN 50022:
Article-No. 1802911
1616