54 PROGRAMMING MANUAL 516532 B PUBLICATION DATE 1 JUN 2007.DOC
motor drive.
6. Check the contactor power supply motor
drive. (contactor is not available on all
machine types)
If the contactor is broken, replace the contactor.
HELP CODE H58 : LOCK ACTIVE
Help Code H58 occurs when at standby the door lock is locked nevertheless the door is open.
Before further usage of washing machine, door lock must be unlocked first by technical intervention.
DIAGNOSE(ERR78):
1. Check correct functioning of door lock
system.
If door lock system is broken repair door lock system.
HELP CODE H59 : LOCK START
Help Code H59 occurs when at startup the door is locked nevertheless the door is open.
Before further usage of washing machine, door lock must be unlocked first by technical intervention.
DIAGNOSE(ERR79):
1. Check correct functioning of door lock
system.
If door lock system is broken repair door lock system.
HELP CODE H60 : UNDEFINED FREQUENCY INVERTER ERROR CODE
This fault should never occur. Inform the manufacturer.
HELP CODE H61 : THT TIME OUT
Help Code H61 occurs when the software can not handle the THT fault of the frequency inverter.
This fault is a specific fault of the frequency inverter caused by an over current.
DIAGNOSE(ERR28):
1. Check if the correct machine type is
selected in the Configuration Menu.
If the wrong machine type is selected, enter the right
machine type
2. Check if the correct inverter parameters
have been implemented.
Load the correct Inverter parameters.
3. Check if the fault is persistent If the fault is persistent, contact the manufacturer
HELP CODE H62 : OV3 TIME OUT
Help Code H62 occurs when the software can not handle the OV3 fault of the frequency inverter. This fault
is a specific fault of the frequency inverter caused by an over voltage during deceleration.
DIAGNOSE(ERR29):
1. Check if the correct machine type is
selected in the Configuration menu.
If the wrong machine type is selected, enter the right
machine type
2. Check if the correct inverter parameters
have been implemented.
Load the correct Inverter parameters.
3. Check if there was a high unbalance during
extraction, which can be caused by putting
only half loads in the machine.
Put always a full load in the machine drum.
Do not put other material than textile linen (fabrics)
in the machine.
4. Check if the fault is persistent If the fault is persistent, contact the manufacturer