16022498
Revision 0
November 2003
Gas
Freestanding
Range
This Base Manual covers general information
Refer to individual Technical Sheet
for information on specific models
This manual includes, but is
not limited to the following:
Service
This manual is to be used by qualified appliance
technicians only. Maytag does not assume any
responsibility for property damage or personal
injury for improper service procedures done by
an unqualified person.

Other manuals for Maytag MGR5755QD

Questions and Answers

  • D
    donaldlopezSep 9, 2025
    Why does my Maytag Ranges keep sparking after turning it off?
    • S
      Scott RamirezSep 9, 2025
      If your Maytag range continues to spark after the knob is turned to the OFF position, replace the switch/harness. If excessive spillovers are causing the shorting, consider educating the customer about proper cleaning. Alternatively, the switch may have slipped off the valve; carefully reposition it and rotate from OFF to high several times to ensure it's not broken.
  • A
    Angela GeorgeSep 7, 2025
    Why is there no gas flow to the burner on my Maytag Ranges?
    • J
      john97Sep 7, 2025
      If gas is not flowing to the burner and the ignitor glows red on your Maytag range, check the ignitor current draw (it should be between 3.2 and 3.6 Amps); replace the ignitor if it fails this test. Verify that the gas pressure is correct: natural gas should be at 4" WCP, and LP gas should be at 10" WCP. Check the gas valve for continuity. Also, make sure all wire connections are clean and tight, and replace any broken wires.
  • W
    whollandAug 22, 2025
    How to fix a Maytag MGR5755QD Ranges burner that won't ignite?
    • R
      Ricardo DeanAug 22, 2025
      If your Maytag range burner won't ignite and there's no spark when you turn the knob to “LITE”, start by verifying that there's 120 VAC to the range at the wall outlet. Then, check the micro switch contacts. Also, inspect the wiring against the wiring diagram and make sure all connections are correct and tight. If these steps don't resolve the issue, check the spark module according to testing procedures. Finally, clean the electrode or burner cap. If the electrode, electrode wire, or electrode socket is cracked or broken, replace the electrode.
  • K
    Katie ChapmanSep 5, 2025
    What to do if gas flows to my Maytag Ranges burner but it doesn't light?
    • M
      Margaret AcevedoSep 5, 2025
      If gas is flowing to the bake/broil burner but it's not lighting on your Maytag range, reposition the ignitor closer to the burner. Also, clean any dirt or grease from the orifice or burner. Check for correct gas pressure (4" WCP for natural gas and 10" WCP for LP gas). Finally, verify that there isn't a power outage and that the circuit breaker hasn't tripped.
  • L
    Lisa MarquezSep 4, 2025
    What to do if my Maytag MGR5755QD oven is not working?
    • J
      James KellerSep 4, 2025
      If your Maytag range's oven isn't working in bake or broil mode, first check for 120 VAC at the control. If there's no voltage, check the power source. If there is voltage to the control, check for 120 VAC to the ignitor; if there's no voltage, replace the control. Also, make sure all wire connections are clean and tight, and replace any broken wires.
  • A
    Amanda FletcherSep 2, 2025
    Why won't my Maytag MGR5755QD burners ignite?
    • N
      Natasha RobinsonSep 3, 2025
      If the burners on your Maytag range won't ignite and there's no spark, start by cleaning the burner cap to ensure a good ground. If that doesn't work, the spark module might be weak or faulty and require replacement. Also, verify that the gas pressure is correct: 4” WCP for natural gas and 10” WCP for LP gas.
  • L
    Lauren WestSep 1, 2025
    Why is the flame uneven on my Maytag MGR5755QD Ranges?
    • J
      James RobinsonSep 1, 2025
      If the flame is uneven on your Maytag Ranges, burner ports may be clogged.
  • A
    asmithAug 31, 2025
    Why is my food not broiling properly or smoking excessively in my Maytag Ranges?
    • S
      Shane PonceAug 31, 2025
      If your Maytag Ranges food is not broiling properly or smokes excessively, check the oven rack positions and make sure aluminum foil was correctly used. Trim excess fat from meat before broiling and avoid using a soiled broiler pan. Preheat the oven for 2-3 minutes before placing food inside, and broil with the oven door closed.
  • A
    Alyssa GilbertAug 30, 2025
    What to do if my Maytag MGR5755QD Ranges oven did not clean properly after self-clean?
    • C
      Carlos KingAug 30, 2025
      If your Maytag Ranges oven didn't clean properly, a longer cleaning time may be needed. Also, excessive spillovers, especially sugary and/or acidic foods, should be removed prior to starting the self-clean cycle.
  • C
    christopher68Aug 28, 2025
    Why is there a strong odor or light smoke when my Maytag MGR5755QD oven is turned on?
    • C
      Cody RamirezAug 28, 2025
      If you notice a strong odor or light smoke when you turn on your Maytag Ranges oven, this is normal for a new range and should disappear after a few uses. Initiating a clean cycle can help burn off the odors more quickly. Turning on a ventilation fan will also help remove the smoke or odor. Excessive food soils on the oven bottom may also cause this.

Summary

Important Information and Contacts

Safety Information and Precautions

Troubleshooting Procedures

Burner Ignition and Operation Issues

Common problems and solutions for surface burner ignition failures.

Oven and Fan Malfunctions

Troubleshooting steps for oven malfunctions and non-operational fan motors.

Testing Procedures

Component Testing Methods

Step-by-step tests for various appliance components to diagnose issues.

Control Panel and Diagnostic Testing

Procedures for testing the control panel and interpreting diagnostic codes.

Disassembly and Reassembly Procedures

Gas Conversion Procedures

Appliance Pressure Regulator Conversion

Steps to adjust the pressure regulator for Natural or LP gas.

Maytag MGR5755QD Specifications

General IconGeneral
BrandMaytag
ModelMGR5755QD
CategoryRanges
LanguageEnglish