For gas dryers apply joint compound or about 1-1/2 wraps of Teflon tape
over threaded connection on the end of the gas pipe. (See figure 11.)
An elbow is recommended, for additional depth, pointing down to allow
the unit to be located further back into the alcove.
Note: Pipe joint compound must be resistant to the action of any liquefied
petroleum gas.
Add additional fitting to connect the 3/8 inch gas pipe to a female threaded
end of a 3/4 inch flexible connector making sure the connection is tight.
DO NOT use excessive force in tightening threads as this may damage Figure 11
internal components.
Check all gas supply connections from service valve for leaks using a soap solution, DO NOT use an
open flame to check for gas leaks. If bubbles occur, tighten the connections and recheck.
NOTE: As a courtesy, many local gas utilities will inspect a gas appliance installation. Check with your
local utility to see if this service is provided in your area.
NOTE: The minimum permissible gas natural or mixed) supply pressure for purposes of input
adjustment is 4.5 inches of water.
Move unit into position, level and tighten the leveling lock nuts on the legs. Secure the vent pipe to the
exhaust duct with a 4 inch vent clamp.