1-2
CONTENTS
- Outline And Dimensions page i – iv
- Safety Precautions page 2
- Installation Diagram page 3
- Installation Of The Indoor Unit page 4
- Installation Of The Outdoor Unit page 6
- Refrigerant Piping Work page 7
- Electrical Wiring Connection page 8
-
Special Precautions When Dealing With R410A Unit
page 11
-
Special Precautions When Dealing With R407C Unit
page 11
- Vacuuming And Charging page 11
SAFETY PRECAUTIONS
Before installing the air conditioner unit, please read the following safety precautions carefully.
! Warning
Installation and maintenance should be performed by qualified persons who are familiar with local code and
regulation, and experienced with this type of appliance.
All field wiring must be installed in accordance with the national wiring regulation.
Ensure that the rated voltage of the unit corresponds to that of the name plate before commencing wiring work
according to the wiring diagram.
The unit must be GROUNDED to prevent possible hazard due to insulation failure.
All electrical wiring must not touch the refrigerant piping or any moving parts of the fan motors.
Confirm that the unit has been switched OFF before installing or servicing the unit.
- Special Precautions When Charging Unit With
Copeland Scroll Compressors page 12
- Accessory Parts page 13
- Indicator Lights page 13
- Overall Checking page 14
- Standard Operation Conditions page 15
- Auto Random Re-start Function page 15
- Service And Maintenance page 15
- Troubleshooting page 16
- Phase Sequencer (Optional) page 16
! Caution
Please take note of the following important points when installing.
Do not install the unit where leakage of flammable gas may occur.
If gas leaks and accumulates around the unit, it may cause fire ignition.
Ensure that the drainage piping is connected properly.
If the drainage piping is not connected properly, it may cause water leakage which will dampen the
furniture.
Do not overcharge the unit.
This unit is factory pre-charged. Overcharge will cause over-current or damage to the compressor.
Ensure that the units panel is closed after service or installation.
Unsecured panels will cause the unit to operate noisily.