10. Fan OFF Delay – HEAT cycle (0-240 seconds) – Time fan is delayed turning OFF after heat
cycle. For no delay, set to 0:00.
Note: This appears only for heat pump or electric heat systems.
Press the
or button to set delay.
CAUTION!: Changing from the default of 0:00 may permanently damage your system.
Press the button to advance to the next screen.
Configuration Mode Settings (continued)
13. Maximum run cycles allowed per hour (d, 2-6).
d = as many as needed, 2-6 = maximum cycles/hour
Press the or button to select.
Press the button to advance to the next screen.
11. Fan ON Delay – COOL cycle (0-120 seconds) – Time fan is delayed turning ON at start of cool
cycle. For no delay, set to 0:00.
Press the
or button to set delay.
CAUTION!: Changing from the default of 0:00 may permanently damage your system.
Press the button to advance to the next screen.
12. Fan OFF Delay – COOL cycle (0-240 seconds) – Time fan is delayed turning OFF after cool
cycle. For no delay, set to 0:00.
Press the
or button to set delay.
CAUTION!: Changing from the default of 0:00 may permanently damage your system.
Press the button to advance to the next screen.
14. Auxiliary Delay ON – (0-30 minutes) – For heat pump systems only. Set the delay time in
minutes for auxiliary heat to be locked out after a call for second stage.
Press the
or button to select.
Press the button to advance to the next screen.