What does Wet operation error (20 times P12 within 200 mins) mean for McQuay MCI16036CCU216A Fan?
- RRyan SanchezSep 14, 2025
The error indicates a wet operation error (20 times P12 within 200 mins) with the McQuay Fan.
What does Wet operation error (20 times P12 within 200 mins) mean for McQuay MCI16036CCU216A Fan?
The error indicates a wet operation error (20 times P12 within 200 mins) with the McQuay Fan.
What does IPM module protection mean for McQuay MCI16036CCU216A Fan?
The error indicates that the IPM module protection has been activated on the McQuay Fan.
What does DC fan motor error mean on a McQuay MCI16036CCU216A Fan?
The error indicates a DC fan motor error with the McQuay Fan.
What does high pressure switch error mean on McQuay MCI16036CCU216A?
The McQuay Fan is showing a high pressure switch error.
What does T3 condenser sensor disconnect error (20 times E14 within 100 mins) mean for McQuay Fan?
The error indicates a T3 condenser sensor disconnect error (20 times E14 within 100 mins) with the McQuay Fan.
What does Compressor phase loss protection ratio protection mean for McQuay MCI16036CCU216A Fan?
The error indicates compressor phase loss protection ratio protection for the McQuay Fan.
What does error code E6 mean on a McQuay Fan?
The error code E6 indicates a T3 Condenser temperature sensor error on the McQuay Fan.
What does Communication error of main chip and IPM chip mean for McQuay MCI16036CCU216A Fan?
The error indicates a communication error between the main chip and the IPM chip in the McQuay Fan.
What does it mean if the Compressor stalls on McQuay MCI16036CCU216A?
The error indicates that the compressor stalls on the McQuay Fan.
What does T5 Discharge temperature abnormal error mean on McQuay MCI16036CCU216A Fan?
The McQuay Fan is showing a T5 Discharge temperature abnormal error.
Lists specific model names for indoor and outdoor units.
Visual overview of indoor and outdoor unit designs.
Highlights key characteristics and benefits of the outdoor unit.
Detailed technical specifications for outdoor units.
Physical dimensions and measurements of the outdoor unit.
Required clearance for installation and maintenance of outdoor units.
Electrical wiring schematics for the outdoor unit.
Electrical properties and performance data of the outdoor unit.
Environmental and operational limits for the outdoor unit.
Noise level measurements for the outdoor unit.
Detailed breakdown of outdoor unit components.
Procedures for diagnosing and resolving outdoor unit issues.
Features, specifications, and installation details for cassette indoor units.
Features, specifications, and installation details for floor/ceiling indoor units.
Important safety guidelines and initial steps for installation.
Procedures for evacuating and leak testing the refrigerant system.
Guidelines for calculating and adding refrigerant charge.
Methods for insulating refrigerant and drainage pipes.
Steps for verifying installation and initial system function.
Wiring schematics for various indoor/outdoor unit combinations.