What does Wet operation error (20 times P12 within 200 mins) mean for McQuay MQC164036CCK216B Fan?
- Eeric96Sep 14, 2025
The error indicates a wet operation error (20 times P12 within 200 mins) with the McQuay Fan.

What does Wet operation error (20 times P12 within 200 mins) mean for McQuay MQC164036CCK216B Fan?
The error indicates a wet operation error (20 times P12 within 200 mins) with the McQuay Fan.
What does IPM module protection mean for McQuay MQC164036CCK216B Fan?
The error indicates that the IPM module protection has been activated on the McQuay Fan.
What does DC fan motor error mean on a McQuay MQC164036CCK216B Fan?
The error indicates a DC fan motor error with the McQuay Fan.
What does high pressure switch error mean on McQuay MQC164036CCK216B Fan?
The McQuay Fan is showing a high pressure switch error.
What does T3 condenser sensor disconnect error (20 times E14 within 100 mins) mean for McQuay Fan?
The error indicates a T3 condenser sensor disconnect error (20 times E14 within 100 mins) with the McQuay Fan.
What does Compressor phase loss protection ratio protection mean for McQuay MQC164036CCK216B Fan?
The error indicates compressor phase loss protection ratio protection for the McQuay Fan.
What does error code E6 mean on a McQuay Fan?
The error code E6 indicates a T3 Condenser temperature sensor error on the McQuay Fan.
What does Communication error of main chip and IPM chip mean for McQuay MQC164036CCK216B Fan?
The error indicates a communication error between the main chip and the IPM chip in the McQuay Fan.
What does it mean if the Compressor stalls on McQuay MQC164036CCK216B Fan?
The error indicates that the compressor stalls on the McQuay Fan.
What does T5 Discharge temperature abnormal error mean on McQuay Fan?
The McQuay Fan is showing a T5 Discharge temperature abnormal error.
Lists model names, dimensions, and power supply for indoor and outdoor units.
Shows images of indoor units (Cassette, Floor-ceiling) and outdoor units.
Details key features of the 16 SEER Top-Discharge Unit, including capacity and design.
Provides detailed technical specifications for outdoor units, including electrical and physical data.
Illustrates outdoor unit dimensions (A, B, C) and refrigerant pipe connection sizes.
Specifies required clearances for installation and maintenance around the outdoor unit.
Presents the electrical wiring diagram for the outdoor unit.
Details the electrical parameters and motor output for outdoor units.
Outlines the operational temperature ranges for cooling mode.
Lists the noise levels (dB(A)) measured for each outdoor unit model.
Provides a visual breakdown of outdoor unit components with part numbers.
Lists fault codes, descriptions, and potential solutions for outdoor unit errors.
Covers features, specifications, dimensions, wiring, and troubleshooting for cassette indoor units.
Covers features, specifications, dimensions, wiring, and troubleshooting for floor & ceiling indoor units.
Covers pipe measurement, connection cautions, and drilling procedures.
Explains procedures for vacuum drying pipes and checking for leaks.
Provides guidelines and calculations for adding refrigerant based on pipe length.
Details material requirements and procedures for insulating refrigerant and drainage pipes.
Outlines the steps and checks required for testing the installed air conditioner.
Shows wiring diagrams for connecting outdoor units with different indoor unit types.