What does Wet operation error (20 times P12 within 200 mins) mean for McQuay Fan?
- KkphillipsSep 14, 2025
The error indicates a wet operation error (20 times P12 within 200 mins) with the McQuay Fan.

What does Wet operation error (20 times P12 within 200 mins) mean for McQuay Fan?
The error indicates a wet operation error (20 times P12 within 200 mins) with the McQuay Fan.
What does IPM module protection mean for McQuay Fan?
The error indicates that the IPM module protection has been activated on the McQuay Fan.
What does DC fan motor error mean on a McQuay MCI16060CCU216A?
The error indicates a DC fan motor error with the McQuay Fan.
What does high pressure switch error mean on McQuay Fan?
The McQuay Fan is showing a high pressure switch error.
What does T3 condenser sensor disconnect error (20 times E14 within 100 mins) mean for McQuay MCI16060CCU216A Fan?
The error indicates a T3 condenser sensor disconnect error (20 times E14 within 100 mins) with the McQuay Fan.
What does Compressor phase loss protection ratio protection mean for McQuay MCI16060CCU216A?
The error indicates compressor phase loss protection ratio protection for the McQuay Fan.
What does error code E6 mean on a McQuay MCI16060CCU216A?
The error code E6 indicates a T3 Condenser temperature sensor error on the McQuay Fan.
What does Communication error of main chip and IPM chip mean for McQuay MCI16060CCU216A?
The error indicates a communication error between the main chip and the IPM chip in the McQuay Fan.
What does it mean if the Compressor stalls on McQuay Fan?
The error indicates that the compressor stalls on the McQuay Fan.
What does T5 Discharge temperature abnormal error mean on McQuay Fan?
The McQuay Fan is showing a T5 Discharge temperature abnormal error.
| Model | MCI16060CCU216A |
|---|---|
| Motor Power | 5 HP |
| Phase | 3 |
| Frequency | 60 Hz |
| Voltage | 460 V |
| Fan Diameter | 24 inch |
Lists model names and specifications for indoor and outdoor units.
Visual overview of indoor and outdoor unit designs.
Highlights key characteristics and capabilities of the unit.
Detailed technical specifications and performance data for the outdoor unit.
Provides physical dimensions and measurements for the outdoor unit.
Recommended clearances for installation and maintenance of the outdoor unit.
Electrical schematics for outdoor unit connections.
Electrical properties, voltage, and power output details.
Defines the operational temperature and environmental boundaries.
Specifies the noise output levels of the outdoor unit.
Illustrates the unit’s components with part identification.
Lists common faults, codes, and diagnostic procedures.
Details on cassette-type indoor units, features, and specifications.
Information on floor and ceiling-mounted indoor units, their features and specs.
Important safety and procedural guidelines before installation.
Procedures for evacuating and testing the refrigerant system.
Guidelines for calculating and adding refrigerant.
Instructions for insulating refrigerant and drainage pipes.
Steps for verifying correct installation and system function.
Wiring diagrams for connecting the outdoor unit with various indoor units.