A
Amanda VaughnSep 14, 2025
What does Wet operation error (20 times P12 within 200 mins) mean for McQuay MQC164060CFC216B?
- JJennifer WilsonSep 14, 2025
The error indicates a wet operation error (20 times P12 within 200 mins) with the McQuay Fan.
What does Wet operation error (20 times P12 within 200 mins) mean for McQuay MQC164060CFC216B?
The error indicates a wet operation error (20 times P12 within 200 mins) with the McQuay Fan.
What does IPM module protection mean for McQuay MQC164060CFC216B?
The error indicates that the IPM module protection has been activated on the McQuay Fan.
What does DC fan motor error mean on a McQuay MQC164060CFC216B Fan?
The error indicates a DC fan motor error with the McQuay Fan.
What does high pressure switch error mean on McQuay MQC164060CFC216B Fan?
The McQuay Fan is showing a high pressure switch error.
What does T3 condenser sensor disconnect error (20 times E14 within 100 mins) mean for McQuay Fan?
The error indicates a T3 condenser sensor disconnect error (20 times E14 within 100 mins) with the McQuay Fan.
What does Compressor phase loss protection ratio protection mean for McQuay Fan?
The error indicates compressor phase loss protection ratio protection for the McQuay Fan.
What does error code E6 mean on a McQuay Fan?
The error code E6 indicates a T3 Condenser temperature sensor error on the McQuay Fan.
What does Communication error of main chip and IPM chip mean for McQuay Fan?
The error indicates a communication error between the main chip and the IPM chip in the McQuay Fan.
What does it mean if the Compressor stalls on McQuay MQC164060CFC216B Fan?
The error indicates that the compressor stalls on the McQuay Fan.
What does T5 Discharge temperature abnormal error mean on McQuay Fan?
The McQuay Fan is showing a T5 Discharge temperature abnormal error.
Detailed technical specifications for the outdoor unit models.
Physical dimensions and refrigerant pipe connection sizes.
Required clearance for installation and maintenance of the outdoor unit.
Electrical wiring schematics for the outdoor unit.
Guides for diagnosing and resolving common faults and error codes.
Troubleshooting guide for round-way cassette indoor units.
Troubleshooting guide for floor & ceiling indoor units.
Important precautions and steps before and during installation.
Procedure for removing moisture and checking for leaks in the system.
Guidelines for calculating and adding refrigerant based on pipe length.
Steps and checks required for final system testing after installation.