What does T3 sensor high temperature error mean on my McQuay MQC164036CCK216B Fan?
- TTracy PopeSep 3, 2025
The error indicates a T3 sensor high temperature error (in cooling mode) (20 times P5 error within 180mins) on the McQuay Fan.
What does T3 sensor high temperature error mean on my McQuay MQC164036CCK216B Fan?
The error indicates a T3 sensor high temperature error (in cooling mode) (20 times P5 error within 180mins) on the McQuay Fan.
What does Frequency limitation by voltage mean for McQuay MQC164036CCK216B Fan?
The McQuay Fan's frequency is experiencing limitation by voltage.
What does Frequency limitation by condenser temp mean for McQuay MQC164036CCK216B Fan?
The McQuay Fan's frequency is experiencing limitation by condenser temp.
What does error code E4 mean on a McQuay Fan?
The error code E4 indicates a T4 Outdoor ambient temperature sensor error on the McQuay Fan.
What does error code E5 mean on a McQuay MQC164036CCK216B Fan?
The error code E5 indicates a T5 Discharge temperature sensor error on the McQuay Fan.
Lists model names, dimensions, and power supply for indoor and outdoor units.
Shows images of indoor units (Cassette, Floor-ceiling) and outdoor units.
Details key features of the 16 SEER Top-Discharge Unit, including capacity and design.
Provides detailed technical specifications for outdoor units, including electrical and physical data.
Illustrates outdoor unit dimensions (A, B, C) and refrigerant pipe connection sizes.
Specifies required clearances for installation and maintenance around the outdoor unit.
Presents the electrical wiring diagram for the outdoor unit.
Details the electrical parameters and motor output for outdoor units.
Outlines the operational temperature ranges for cooling mode.
Lists the noise levels (dB(A)) measured for each outdoor unit model.
Provides a visual breakdown of outdoor unit components with part numbers.
Lists fault codes, descriptions, and potential solutions for outdoor unit errors.
Covers features, specifications, dimensions, wiring, and troubleshooting for cassette indoor units.
Covers features, specifications, dimensions, wiring, and troubleshooting for floor & ceiling indoor units.
Covers pipe measurement, connection cautions, and drilling procedures.
Explains procedures for vacuum drying pipes and checking for leaks.
Provides guidelines and calculations for adding refrigerant based on pipe length.
Details material requirements and procedures for insulating refrigerant and drainage pipes.
Outlines the steps and checks required for testing the installed air conditioner.
Shows wiring diagrams for connecting outdoor units with different indoor unit types.