WARNING: BEFORE PERFORMING ANY MAINTENANCE OR REPAIRS, DISCONNECT
THE POWER SUPPLY CABL FROM THE MAINS AND MAKE SURE THAT THE
GENERATOR IS COLD.
10. PREVENTIVE MAINTENANCE SCHEDULE
COMPONENT MAINTENANCE FREQUENCY MAINTENANCE PROCEDURE
Fuel tank Empty and rinse the tank with clean
fuel every 150-200 working hours
Empty and rinse the tank with
clean fuel (SEE PAR. 9)
Air outlet and anti-
dist lters
Clean and replace according to
necessity
Contact after-sales centre
Air inlet lter Clean or replace every 500 working
hours or when necessary
Contact after-sales centre
Fuel lter Clean or replace every 2 working
seasons or when necessary
Contact after-sales centre
Igniter Clean or replace every 1000
working hours or when necessary
Contact after-sales centre
Fan blades Clean and replace according to
necessity
Contact after-sales centre
11. TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION
The generator
does not start
1. Generator blocked
2. Starter switch in “OFF” position
(0)
3. No power supply
4. Power supply cable interrupted
5. Control card blocked
6. Incorrect setting of the room
thermostat (where present)
1. Reset the generator (SEE PAR.
6.2)
2. Take the “ON/OFF” switch to the
“ON” (|) position (SEE FIG. 3-4)
3. Insert the power supply cable into
the mains socket correctly
4. Contact after-sales centre
5A. Reset the generator (SEE PAR.
6.2)
5B. Contact after-sales centre
6. Act on the room thermostat, taking
it to a higher temperature than that
of the work environment (SEE FIG.
5-6)
The motor starts
but the ame is not
triggered
1. No fuel
2. Incorrect pump pressure
3. Igniter dirty
4. Fuel lter dirty
5. Nozzle dirty
6. Presence of foreign
substances in the tank
7. Flame control device broken
1. Top-up fuel and reset the generator
2. Regulate the pressure of the
compressor (SEE PAR. 7)
3. Contact after-sales centre
4. Contact after-sales centre
5. Contact after-sales centre
6. Empty and ll the tank with clean
fuel (SEE PAR. 9)
7. Contact after-sales centre
The fan is blocked
or turns slowly
1. Pump rotor blocked
2. Motor broken
1. Contact after-sales centre
2. Contact after-sales centre
ATTENTION: ON RE-START, MAKE SURE THE GENRATOR HAS BEEN SET VIA THE
RELATIVE BUTTON. (SEE PAR. 6.2)