Use
WARNING: Do not start the pump until the pump chamber is lled with water.
1. Rotate the impeller before starting and
check that it can rotate freely.
2. Unscrew the ller plug, ll the pump
chamber with clean water and ret
the ller plug when the chamber is
completely lled and free of residual air.
3. Initially set the valve at a low ow and adjust the ow to the desired level once the water has
started to ow (approved intervals are shown on the type plate).
MAINTENANCE
NOTE:
Disconnect the pump from the mains supply, before any maintenance is performed on it.
Do not touch the electric garden pump until it has been switched o and disconnected from the
power supply for at least ve minutes.
Storage and maintenance
If there is a risk of frost, open the drain plug and drain all water from the pump. Fill the pump
with water before starting it again.
Drain the water from the pump, if it is not going to be used for a prolonged period.
Clean the pump housing, impeller and stand, apply anti-corrosion oil and store in a dry place
with good ventilation.
If the pump has not been used for a long time, it should be lled with water before starting.
Pay attention to ventilation at high ambient temperatures and/or high humidity. Avoid
condensation on electrical components - risk of electrical fault.
If the motor becomes very hot or the motor sounds abnormal, immediately shut-o the pump
and check according to the troubleshooting chart.