13
25
Do not use closer
than 20mm
20
15
10
5
0 15 30 45 60 75 90 105 120 135 150
Operating Distance (mm)
Frequency Rate (Hz)
Optimum Frequency Vs Operating Distance for 924IPS
Requires optional BarMaster Remote Programmer.
Maintenance
Ionising bars become contaminated with usage. Dirt build-up on the body of the
ioniser and, particularly on the pins, will cause a drop in performance. To get the
best from your bar, it should be cleaned as part of regular machine maintenance.
If regular cleaning is not carried out, the bar will detect the drop in performance
and trigger the Clean Pin alert. The LED will ash red and the output signal will be
activated.
Before cleaning, ensure that the equipment is switched off.
Emitter pins can be cleaned very effectively with a brush. A dry toothbrush is ideal.
Make sure the central divider is also cleaned and the pin surface of the bar.