500 V. Analogue Insulation & Continuity Testers
M BM100/4 and BM101/4
User Guide
Guide de l’utilisateur
Gebrauchsanleitung
Guía del usuario
SAFETY WARNINGS
Safety Warnings and precautions m u s t be read and
understood before the instrument is used. They m u s t
be observed during use.
The circuit under test must be de-energised and
isolated before Insulation, Resistance, or Continuity
tests are made.
During an insulation test, the circuit must not be
touched.
After insulation tests, capacitive circuits must be
allowed to discharge before disconnecting the test
leads.
Test leads, including prods and crocodile clips must
be in good order; clean, and with no broken or
cracked insulation.
Replacement fuses must be of the correct type and
rating.
BM 100/4 Only
U.K. Safety Authorities recommend the use of fused
test leads when measuring voltage on high energy
systems.
When making a voltage measurement, the 'Test' push
must not be pressed.
NOTE
T H E I N S T R U M E N T S M U S T O N Y B E U S E D B Y S U I TA B LY T R A I N E D A N D C O M P E T E N T P E R S O N S
.
Symbols used on the instrument
Caution: Refer to accompanying notes.
Equipment protected throughout by Double Insulation
(Class II).
Equipment complies with relevant EU Directives
Question and Answer IconNeed help?

Do you have a question about the Megger BM100/4 and is the answer not in the manual?

Megger BM100/4 Specifications

General IconGeneral
Test Voltage100V, 250V, 500V, 1000V
Battery Type8 x AA batteries
Continuity Test Current200mA
Voltage Measurement0 to 600V AC
Measurement Range (Resistance)0.01Ω to 1000Ω
Test Current200mA
Power SupplyBattery

Summary

SAFETY WARNINGS

Symbols Used on the Instrument

Explanation of instrument symbols, double insulation, and EU directives.

OPERATION

Preliminary Test Lead Check

Inspect leads, connect terminals, short prods, verify zero reading.

Continuity Testing

Set 2Ω/200Ω, connect leads, press Test, read scale.

Insulation Testing

Set 200MΩ, connect leads, press Test, read top scale.

Resistance Testing (BM101/4 Only)

Set 1MΩ, connect leads, press Test, read scale.

SPECIFICATION

Technical Specifications Overview

Covers ranges, voltages, currents, AC voltage, impedance, discharge, accuracy, humidity, temp.

Power, Fuses, and Safety Compliance

Details on power supply, fuses, safety standards, EMC, weight, dimensions, cleaning.

ACCESSORIES

Supplied and Optional Accessories

Lists items supplied with and optional accessories for the instrument.

Publications

Lists available publications related to the instrument.

REPAIR AND WARRANTY

Service and Repair Information

Contact details for repair, spare parts, and approved companies.

Returning Instrument for Repair

Procedure for sending the instrument for repair.

Related product manuals