Megger DET4TD2 User Manual

Megger DET4TD2
63 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
M
DET Series
EARTH GROUND ELECTRODE TESTERS
USER GUIDE

Other manuals for Megger DET4TD2

Question and Answer IconNeed help?

Do you have a question about the Megger DET4TD2 and is the answer not in the manual?

Megger DET4TD2 Specifications

General IconGeneral
Accuracy±(2% + 2 digits)
Operating Temperature-20 °C to +50 °C
IP RatingIP54
Storage Temperature-20 °C to +60 °C
Power Source6 x 1.5 V AA batteries
Safety RatingCAT IV
Measurement Range0.01 Ω to 2000 Ω
Test Current200 mA
Voltage Measurement Range0 to 600 V AC/DC
DisplayLCD
Power Supply6 x 1.5 V AA batteries
Weight0.5 kg
Test Voltage250 V, 500 V, 1000 V

Summary

Safety Warnings and Precautions

General Safety Precautions

Summarizes critical safety warnings and advice for using the instrument.

Live Earth Safety Precautions

Specific warnings and precautions for situations involving live earth connections.

Battery Management

Fuse Information

Description of Tests

Principle of Operation: Two-Terminal Resistance Measurement

Explains the method for measuring resistance using two earth points.

Principle of Operation

Three-Terminal Resistance Measurement

Explains the 'fall of potential' test method for measuring earth electrode resistance.

Three-Terminal Resistance Measurement using ART

Explains the ART method for measuring resistance without disconnecting the electrode.

Two-Clamp Stakeless Resistance Measurement

Explains the stakeless test method using VCLAMP and ICLAMP for resistance measurement.

Four-Terminal Resistivity Measurement

Explains the principle for measuring soil resistivity using four stakes.

Ground Noise Voltage Measurement

Connection for Noise Voltage Measurement

Instrument connection diagrams for measuring ground noise voltage.

Two-Terminal Resistance Measurement

Connection for Two-Terminal Measurement

Instrument connection diagrams for two-terminal resistance tests.

Two-Terminal Resistance Measurement Procedure

Steps for performing a two-terminal resistance test on various models.

DET3TA Two-Terminal Resistance Measurement

Three-Terminal Resistance Measurement

Connection for Three-Terminal Measurement

Instrument connection diagrams for three-terminal resistance tests.

Three-Terminal Resistance Measurement Procedure

Steps for performing a three-terminal resistance test on various models.

DET3TA Three-Terminal Resistance Measurement

DET3TA Connection and Procedure

Connection diagram and steps for performing a three-terminal resistance test on DET3TA.

Three-Terminal Resistance Measurement with Lead Null

Connection for Lead Null Measurement

Instrument connection diagrams for three-terminal resistance measurement with lead null.

Four-Terminal Resistivity Measurement

Connection for Four-Terminal Measurement

Instrument connection diagrams for four-terminal resistivity measurements.

Measurement of Ground Current

Connection for Ground Current Measurement

Instrument connection diagrams for measuring ground current using ICLAMP.

Three-Terminal Resistance Measurement using ART

Connection for ART Measurement

Instrument connection diagrams for three-terminal resistance measurement using ART.

Three-Terminal Resistance Measurement with Lead-Null using ART

Connection for ART Lead Null Measurement

Instrument connection diagrams for ART lead null resistance measurement.

Two-Clamp Stakeless Measurement

Connection for Stakeless Measurement

Instrument connection diagrams for two-clamp stakeless resistance measurement.

ICLAMP Calibration Procedures

Calibration Adaptor Operations

Preventive Instrument Maintenance

Accessory Specifications

Related product manuals