Meggitt ACT1000 - User Manual

Meggitt ACT1000
50 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Meggitt Control Systems
11661 Sorrento Valley Road, San Diego CA 92121, USA
Precision Engine Controls Corporation d/b/a Meggitt Control Systems
Tel: +1 (858) 792 3217
Fax: +1 (858) 792 3200
www.meggitt.com
User manual
ACT1000/ACT1000HF Electric linear actuator
SD-6029 Rev 2
April 2018
WARNING – This information is subject to the export of which is restricted by the Export
Administration Act and the Export Administration Regulations (EAR), 15 C.F.R. parts 730-774,
diversion contrary to U.S. law is prohibited. The export, re-export, transfer or re-transfer of this
technical data to any other company, entity, person, or destination, or for any use or purpose other
than that for which the technical data was originally provided is prohibited without prior written
approval and authorization under applicable export control laws.
EAR Export Classification: ECCN: EAR99

Questions and Answers

  • M
    Monica PatelAug 18, 2025
    How to fix communication interface inoperative on Meggitt ACT1000 Controller?
    • A
      Amber ColonAug 18, 2025
      If the Meggitt Controller communication interface is inoperative, check the following: * Ensure the communication wires are correctly connected to both the actuator and the laptop PC. * Verify that there is 120 VDC Primary System Power at the Actuator. * Check the laptop/PC com port. * Remove any RESET or RUN commands.
  • G
    Gabrielle ThompsonAug 20, 2025
    Why Meggitt ACT1000 Controller actuator does not hold consistent position?
    • K
      Kelly RyanAug 21, 2025
      If the Meggitt Controller actuator does not hold a consistent position and oscillates or dithers, it could be due to: * A varying position demand signal. Ensure a stable position demand at the actuator. * No or low 120 VDC power. Make sure there is 120 VDC at the actuator.
  • J
    jessica23Aug 23, 2025
    Why Meggitt ACT1000 Controller actuator does not track position demand?
    • J
      Joshua MooreAug 23, 2025
      If the Meggitt Controller actuator does not track the position demand, ensure the following: * Position demand is greater than 4.1 mA at the actuator. * RUN command is present at the actuator.
  • V
    Vincent BurnettAug 26, 2025
    How to troubleshoot no motor current feedback on Meggitt ACT1000?
    • D
      Dale ThorntonAug 26, 2025
      If there is no motor current feedback from the Meggitt Controller actuator, check the following: * Verify the motor current signal is correctly connected. * Ensure there is 120 VDC at the actuator. * Confirm the RUN command is present at the actuator.
  • M
    Megan HicksAug 28, 2025
    What causes no actuator feedback on Meggitt ACT1000 Controller?
    • A
      Amanda SheltonAug 28, 2025
      If there is no actuator feedback from the Meggitt Controller, verify the feedback signal is correctly connected. Also, ensure 120 VDC is present at the actuator. If the actuator has auto shut down for self-protection, upload the fault file to check for shutdown faults. Finally, check for actuator contamination and ensure the RUN command is present at the actuator.
  • C
    Carrie WongAug 31, 2025
    What to check if Meggitt Controller actuator inoperative with NO FAULT alarm?
    • A
      apenningtonAug 31, 2025
      If the Meggitt Controller actuator is inoperative and there is NO FAULT alarm, ensure 24 VDC RUN and position command at the actuator.
  • C
    Cynthia JenkinsSep 2, 2025
    Why Meggitt ACT1000 Controller actuator moves toward HOME then stops?
    • S
      Samantha WalkerSep 2, 2025
      If the Meggitt Controller actuator moves toward HOME then stops, ensure a consistent 24 VDC RUN command and position demand signal. Also ensure position command at actuator.
  • S
    Scott JohnsSep 4, 2025
    What to do if Meggitt ACT1000 actuator moves toward HOME intermittently?
    • L
      Larry SaundersSep 4, 2025
      If the Meggitt Controller actuator moves toward HOME intermittently, ensure a consistent 24 VDC RESET command.
  • N
    Nathan MillerSep 7, 2025
    How to clear Warning FAULT alarm on Meggitt ACT1000 Controller?
    • A
      Amy ThomasSep 7, 2025
      If there is a Warning FAULT alarm on the Meggitt Controller, upload the fault file to identify the source of the fault and clear the indicated fault.
  • W
    williamsonstevenSep 9, 2025
    What causes shutdown fault alarm on Meggitt Controller?
    • R
      Robert MccarthySep 9, 2025
      If the Meggitt Controller displays a shutdown FAULT alarm, allow the actuator to cool and restart it. Reduce the ambient temperature if the electronics or motor winding temperature is out of range. Check for actuator contamination.

Summary

Installing the ACT1000;ACT1000 HF

Before Beginning Installation

Inspection, identification nameplates, and initial setup steps.

Installation Processes and Considerations

Recommended installation steps, noise guidelines, and environmental factors.

General Specification Summary

Mechanical Installation

Mounting and Dimensions

Details on mounting types, dimensions, clevis, flange, and extension rod.

Electrical Connections

Grounding, Conduit Seals, and Power

Ground connection, conduit seals, and power connection details.

Power Supply and Signal Requirements

Power Supply Requirements

Detailed table of voltage, current, and capacitance requirements for the power supply.

Signal Connections

Information on the 25-wire signal harness, wiring, and communication interfaces.

Understanding the ACT1000;ACT1000 HF

System and Electrical Description

Overview of the actuator's system architecture and electrical components.

Mechanical Description

Description of the actuator's main mechanical assemblies.

Operating the ACT1000;ACT1000 HF

Powering Up and Homing

Process of powering up, finding home position, and holding current state.

Motion Control and Positioning

Controlling motion, stop position, deadband, hysteresis, and span.

Setup and Maintenance

Changing Set-up Parameters

How to change set-up parameters using ActWiz software via RS485.

Maintenance and Refurbishment

Scheduled inspections and factory refurbishment recommendations.

Troubleshooting

Troubleshooting Common Issues

Identifying and resolving common failures and electrical continuity checks.

Appendices

Decommissioning and Disposal

Recommended practices for decommissioning and disposal of the product.

Glossary

Glossary of terms used in the manual.

Meggitt ACT1000 Specifications

General IconGeneral
BrandMeggitt
ModelACT1000
CategoryController
LanguageEnglish