Changer Operation
Figure 4: TRC-60X0, TRC-6510 Option
Switch Location
Figure 5: TRC-6512 Option Switch Location
Table 3: TRC6510 Option Switches
Switch Setting Function
1 (US/Canadian
acceptance)
2 (Quarter tube
level)
3 (Dollar coin
acceptance)
4 (Acceptance
status)
ON
ON
US and Canadian coin
acceptance
OFF US coin acceptance
OFF Stores 69 quarters for change
Stores 6 quarters for change
ON
OFF Disables dollar coin acceptance
Enables dollar coin acceptance
-
if programmed
ON
OFF Maximum security
Maximum acceptance
Table 4: TRC6512 Option Switches
Switch Setting Function
1 (Quarter tube
level)
ON Stores 4 to 6 quarters for
change (LOW)
OFF Stores 67 to 74 quarters for
change (HIGH)
2 (Dollar coin
acceptance)
3 (Acceptance
status)
ON
OFF Rejects $ coins
Accepts $ coins
ON
OFF Maximum acceptance
Maximum security
6
Option Switches
Table 2: TRC60X0 Option Switches
Switch Setting Function
1 (US/Canadian
acceptance
2 (Quarter tube
level)
3 (Dollar coin
acceptance)
4 (Dollar coin
acceptance -
25¢ coin tube
dependency)
ON
ON
Accepts US and Canadian
coins -
if programmed
OFF Accepts US coins only
OFF Stores 69 quarters for change
Stores 6 quarters for change
ON
OFF Disables dollar coin acceptance
Enables dollar coin acceptance
-
if programmed
ON
OFF Accepts dollar coin
with
quarters in 25¢ tube
Accepts dollar coins
without
quarters in 25¢ tube