MEINBERG Radio Clocks - www.meinberg.de
2013-07 Page 1
Serial connecon to a Lanme
without a Display - LANTIME V5 Firmware
Serial connecon setup
The gure shows a LANTIME M100 connected with
power, network, GPS antenna and a serial connecon
between a LANTIME and a computer.
1
USB to Serial Adapter
If you do not use a NULL-MODEM cable you have to connect
a signal changer (TxD - RxD)
2
and a gender changer
3
if
the used adapter cable is equipped with an male connector
1
2
3
In the LANTIME NTP server without a display one has to start
a serial connecon between a PC and the LANTIME in order
to check or assign a Lanme IP address. The serial connecon
can be set up with a NULL-MODEM cable or via an USB to
Serial Adapter.
1. Open an SSH client on your PC (e.g. PuTTy.exe). Type in
the serial port of the PC and the connecon values for
speed and framing, for our example 38400 Baud / 8N1 as
shown in Fig. 1. Conrm with Open buon.
Figure 1: Serial connecon with an SSH client.
2. LOGIN with a Username and a Password-
Default values root / meserver.
3. Type in setup to enter the Lanme Conguraon window.
4. Choose Ethernet menu (in the lower le corner) and
conrm with „Enter“ to enter the Ethernet Conguraon
window. Secondly, choose Ethernet 0 to proceed to the
Ethernet Conguraon Line 0 as shown in Fig. 2.
Figure 2: Ethernet Conguraon Line, where the Lanme
IP address is congured .
5. Note down the IP address and Netmask as assigned from
a DHCP.
6. Close this window and exit the SSH client.
7. Connect the LANTIME with your network and start
the WEB interface in your browser via the congured
IP-Address.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Meinberg LANTIME Series and is the answer not in the manual?

Meinberg LANTIME Series Specifications

General IconGeneral
Network ProtocolsIPv4, IPv6
Time ProtocolsNTP, SNTP
Synchronization SourcesGPS, GLONASS, Galileo, IRIG, DCF77, PTP, NTP
ManagementSNMP
SecurityAccess Control Lists
RedundancyDual power supply, Dual network interfaces
Form Factor1U rack-mountable
Input/Output InterfacesIRIG
Power Supply100-240V AC
Operating Temperature0°C to +50°C

Related product manuals