4. Technician settings (cont’)
P1 – Offset for temperature readings calibration
Range: -6…+6°C / -9…+9°F.
Default: 0°C / 0°F.
P2 Set point limit for cooling
Range: 5…35°C / 41…90°F.
Default: 5°C / 35°F.
P3 – Set point limit for heating
Range: 5…35°C / 41…95°F.
Default: 35°C / 95°F.
P5 – Lock the [Mode] button
“01” - [Mode] button Locked
“00” - [Mode] button unlocked (default)
P6 – Lock the [On/Off] button
“01” - [On/Off] button Locked
“00” - [On/Off] button unlocked (default)
P4 – Lock the [Fan] button
“01” - [Fan] button Locked
“00” - [Fan] button unlocked