5. Do not get in eyes, on skin, or on clothing. Do not breathe vapors or gas.
6. Prevent entry to sewers and public waters.
7. Stop the source of the release, if safe to do so. Consider the use of water spray to disperse vapors.
8. Isolate the area unl gas has dispersed. Venlate and gas test area before entering. Contact
competent authories aer a spill.
7. TROUBLESHOOTING
Symptom Inspecon Soluon
The unit is
not
operang.
Check the power connecon in
securely.
Insert the power cord securely into
the wall Outlet.
Check if the water full?
Empty the drain pan by remove the
rubber plug.
Check the room temperature.
The range of operang temperature
is 5-35°C.
The unit
works with
reduced
capacity.
Check the air filter for dirt. Clean the air filter as necessary.
Check if the air duct is blocked. To clear the obstacle.
Check if the room door or
window is open.
Keep the door and windows closed.
Check if the desired operang
mode is selected and the
temperature is properly set.
Set the mode and temperature at
proper set-point according the
manual.
The exhaust hose is detached.
Make sure the exhaust hose is
securely aached.
Water
Leakage
Overflow while moving the unit.
Empty the water tank before
transport.
Check if the drain hose is kinked
or bends.
Straighten the hose to avoid a trap
exisng.
Excessive
Noise
Check if the unit is securely
posioned.
Place the unit on horizontal and
firm ground.
Check if any loose, vibrang
parts.
Secure and ght the parts.
Noise sounds like water flowing.
Noise comes from flowing
refrigerant. This is normal.
Error
Codes
E0
Communicaon faults between
main PCB and display PCB.
Check the wiring harness of the
display PCB for damage.
E1
Ambient temperature sensor
failure
Check connecon or replace it. To
clean or replace the temperature
E2
Coil temperature sensor failures.
Check connecon or replace it. To
clean or replace the temperature
Ft
Condensate water high level
alarm.
Empty the drain pan by removing
the rubber plug.
40