EasyManuals Logo

Mercury 225 OptiMax Manual

Mercury 225 OptiMax
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #57 background imageLoading...
Page #57 background image
OPERATION
49
4. Set the lanyard stop switch to the "RUN" position. Refer to
General Information ‑ Lanyard Stop Switch.
19791
5. Shift outboard to the neutral ("N") position.
N
26838
6. For the initial start of a new engine, or for an engine that ran
out of fuel or was drained of fuel, the fuel system should be
filled as follows:
a. Squeeze the fuel line primer bulb until it feels firm.
b. Turn the ignition key switch to the "ON" position for three
seconds. This operates the electric fuel pump.
c. Turn the ignition key switch back to the "OFF" position, and
squeeze the primer bulb again until it feels firm. Turn the
ignition key switch to the "ON" position again for three
seconds. Continue this procedure until the fuel line primer
bulb stays firm.
7. Do not advance the throttle‑only feature on the remote control
for starting.
27242

Table of Contents

Other manuals for Mercury 225 OptiMax

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mercury 225 OptiMax and is the answer not in the manual?

Mercury 225 OptiMax Specifications

General IconGeneral
Engine TypeV6
Horsepower225 HP
Fuel Induction System2-stage Direct Fuel Injection (DFI)
Alternator Output60 amp / 756 watt
Weight505 lbs / 229 kg
Cylinders6
StartingElectric
Gear Ratio1.75:1
Displacement3.0L
Shaft Length20", 25"

Related product manuals