EasyManua.ls Logo

Mercury 520 Bravo Sterndrive - Draining Water from the Cool Fuel Module

Mercury 520 Bravo Sterndrive
123 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MANUAL DRAIN SYSTEM
a - Starboard side blue drain plugs
b - Port side blue drain plug
Air‑Actuated Single‑Point Drain System
BOAT IN THE WATER
NOTE: This procedure is written for the air pump that was shipped with the
engine from the factory. However, any air source can be used.
1. Close the seacock (if equipped) or remove and plug the water inlet hose.
2. Obtain the air pump.
3. Remove the threaded cap from the air connection.
4. Ensure that the lever on top of the air pump is against the handle
(horizontal).
5. Install the air pump on the air connection.
6. Pull the lever on the air pump (vertical) to seal the pump to the
connection.
a
b
a
53834
COLD WEATHER OR EXTENDED STORAGE
92 eng

Table of Contents