WIRING AND BATTERY INFORMATION
20 eng
4. Connect a jumper cable (common ground bond) from the trolling
motor battery "d" negative (–) terminal to the engine battery
negative (–) terminal.
NOTE: Vessels with multiple batteries, must have a common ground
bonding circuit. Not establishing a common ground between the vessel
batteries, may cause severe corrosion, electrolysis, or an electrical
shock.
a - Power cables to trolling motor
b - 50 amp manual reset circuit breaker
c - Trolling motor battery "c"
d - Trolling motor battery "d"
e - Series cable connection
f - Common ground bond
g - Engine starting battery
h - Power cables to engine
RED
BLK
BLK
REDRED
a
b
c
44328
f
e
g
d
h