7I76 27
REFERENCE INFORMATION
SSLBP
CS REGISTER AFTER DOIT
After a successful DOIT command, or normal start with SSLBP versions >28
bytes 0 through 2 of CS register are the same as after a start command but in addition, the
previously invalid byte 3 of the CS register contains remote fault information:
Byte3 = REMOTE_FAULTS
Bit 7 = LBPCOMFault
Bit 6 = IllegalMode Fault
Bit 5 = LowVoltageFault
Bit 4 = HighVoltageFault
Bit 3 = OverCurrentFault
Bit 2 = OverTempFault
Bit 1 = NoEnableFault
Bit 0 = WatchdogFault