ALL INSTALLATION OPERATIONS MUST BE CARRIED OUT WITH THE ENGINE OFF.
Before starting installation, carefully asses the position of the device, according to the available space, to the length
of the power cables, and to the horizontal position that it needs to maintain.
The product needs to be installed in an area that is only accessible to the service sta (Service Access Area On).
Carefully follow the steps outlined in this manual.
• Installation sta are not authorised to remove warranty seals and/or access the inside of the product and accesso-
ries.
• The sta in charge of the installation is not authorised to alter and/or adapt the product and its relative accessories.
The manufacturer assumes no responsibility for damages caused to property and/or people, caused by the in-
correct installation of the product.
ATTENTION: Risk of explosion if the internal batteries are replaced with non-equivalent models, other than those
contained in the product.
INSTALLATION MANUAL
MOTORCYCLE TELEMATIC ALARM
T.30 - Def-Com 30
EN
5040342900-WEB
KIT COMPOSITION
WARNINGS
A
ALARM
CONTROL UNIT
B
ALARM
WIRING
E
ALARM
ACCESSORY BAG
G
DETERGENT
WIPE
D
TELEMATIC
CONTROL UNIT
C
CONNECTION
HARNESS
F
TELEMATIC
ACCESSORY BAG
Power supply: ...............................................................................................................12Vdc (10V-15V)
Working temperature: ...........................................................................between -25°C and +85°C
Protection rating: .............................................................................................................................. IP 65
Application classi cation: .................................................................................................motorcycle
ALARM CONTROL UNIT: TECHNICAL SPECIFICATIONS
Power supply: ..............................................................................................................12Vdc (10V-24V)
Working temperature: ......................................................................... between -30°C and +80°C;
Protection rating: ............................................................................................................................. IP 65
Application classi cation: .................................................................................................motorcycle
TELEMATIC CONTROL UNIT: TECHNICAL SPECIFICATIONS
Question and Answer IconNeed help?

Do you have a question about the Meta System T.30-Def-Com 30 and is the answer not in the manual?

Summary

Kit Composition and Technical Specifications

Alarm Control Unit: Technical Specifications

Details power supply, working temperature, protection rating, and application classification for the alarm control unit.

Telematic Control Unit: Technical Specifications

Details power supply, working temperature, protection rating, and application classification for the telematic control unit.

Installation Warnings and Rules

Applicable Rules

General guidelines stating the manual's applicability to all vehicles and installer responsibilities.

Position of Vehicle During Installation

Illustrates correct and incorrect vehicle positioning for installation, emphasizing outdoor, flat ground, and engine-off conditions.

Alarm Control Unit: Warnings on Device Positioning

Provides guidance on the correct angular positioning of the alarm control unit on a motorcycle.

Telematic Control Unit: Warnings on Device Positioning

Advises on horizontal versus vertical installation and prohibits securing the unit with cables pointing upwards.

Telematic Control Unit: Installation in Horizontal Position

Outlines steps for identifying a flat area, cleaning, and mounting the telematic control unit horizontally.

Wiring Diagrams and Connections

Alarm Control Unit: General Diagram

Presents a general wiring diagram for the alarm control unit, including antenna, battery, and signal connections.

Alarm Control Unit: Ignition Block (Fail Safe System)

Details the ignition block wiring for the fail-safe system, showing connections to the control unit and relays.

Alarm Control Unit: Peripheral Protection

Illustrates connections for peripheral protection, such as buttons to be installed.

Alarm Control Unit: Electrical Connections (connection to the battery)

Explains the correct sequence for connecting the alarm control unit to the motorcycle battery terminals.

Diagnostics and Final Testing

Telematic Control Unit: Diagnostics

Provides a table showing LED indicators for diagnostic information regarding network registration and activation status.

Alarm Control Unit: Final Test

Details the step-by-step procedure for testing the alarm control unit's functionality after installation.

Procedure for the Correct Dismantling of the Telematic Control Unit

Outlines the steps required to correctly remove the telematic control unit from the motorcycle.

Declaration of Conformity

Simplified Declaration of Conformity

Declares compliance with Radio Equipment Directive, specifying frequency bands and power for T.30 and Def-Com 30 models.

Meta System T.30-Def-Com 30 Specifications

General IconGeneral
BrandMeta System
ModelT.30-Def-Com 30
CategoryMotorcycle Accessories
LanguageEnglish

Related product manuals