8
This slow combustion appliance is designed to give you
many years of warmth and service, subject to the following
key factors. These key factors, if not adhered to are the major
causes of unsafe installation, poor performance and ue
blockages and potential product failure.
1. Your Metro wood re must be installed correctly. Metro
recommend a competent and suitably qualied NZHHA
installer.
2. The only fuel to be used in this appliance shall be wood that
meets the following criteria.
Less than 25% moisture content
Has not been treated with preservatives or impregnated
with chemicals or glue,
Is not chipboard, particle board, or laminated board,
Is not painted, stained or oiled
Is not driftwood or other salt impregnated wood
3. The appliance shall be operated at all times in accordance
with the “Installation and Operating Instructions” supplied
with each appliance.
4. It is preferable that
Metro wood res should be installed with
a Metro ECO Flue System.
5. Coal must not be used as a fuel.
Please also note the following important points:
In New Zealand a building consent is required from your
local building authority. The homeowner is responsible for
obtaining this consent.
As correct installation is critical to the performance and safe
operation of your Metro, it is recommended your Metro be
installed by a NZHHA registered installer or a person suitably
qualied in the installation of wood res. Your Metro retailer
will be able to arrange professional installation for you.
During the very rst re your Metro will give off an odour and
fumes as the rebox paint cures. Do not be alarmed; open all
windows and externally opening doors in that room and close
any internally opening doors. This curing process will last for
approximately one hour and is likely to happen this one time.
Properly seasoned (dry) timber is necessary for the Metro to
operate efciently; rewood that contains a high moisture
content will result in ue pipe blockages, reduce heat
output and create other issues.
Note: Once split, Softwood usually takes 12 months to season - Hardwood
can take up to 24 months to season - Wood must be stored in a location
that enables air circulation. Unseasoned wood stored in a closed
woodshed without air circulation will still be unseasoned 12 months later.
• It is critical that the re not be operated with over worn,
faulty or missing door seals. Door seals will harden over time
and become over-worn (3-4 years) this will cause air to
leak into the re, causing the appliance to ‘over re’.
It is critical that the re not be operated with over worn,
faulty or missing bricks, bafe plate, bafe extension
(white board on the bafe plate)
It is critical that the re not be operated with cracked, or
broken door glass.
Please note, the above 3 points require regular inspection/
maintenance (every time the ash bed is cleaned out, generally
3-5 times a season) and if not maintained will void the rebox
warranty. A glowing rebox or lower uepipe is just one sign
you are over ring your appliance. Please ensure you keep your
proof of purchase/receipt on any parts you purchase.
For optimum performance fuel must be loaded so the logs
lay “front to rear” in preference to laying across the width of
the rebox. Spaces should be left between the logs to enable
oxygen to get to as much of the surface of the fuel as possible.
A small hot re loaded frequently is more efcient than a
large re burning on a low setting.
A key feature of all LTD Metro’s is their ability to burn at a
very low rate. To familiarise yourself with correct operation
of this feature, please ensure you read the “extended
burning” section on page 10 of this manual so as not to
void the Metro warranty by incorrect operation.
Your Metro is covered by a full unconditional 12 month
warranty on replacement parts, and a 10 year rebox warranty.
WE HIGHLY RECOMMEND YOU READ THIS ENTIRE
MANUAL AS INCORRECT OPERATION, MISUSE AND/OR
LACK OF MAINTENANCE WILL VOID THE WARRANTY
Any modication of the appliance that has not been
approved in writing by the testing authority is considered
as breaching AS/NZS 4013 and will void the warranty
Do not use ammable liquids or aerosols in the vicinity
of this appliance when it is operating
Do not dry clothes on or near this appliance
Do not use ammable liquids or aerosols to start or
rekindle the re OR store fuel within the Metro’s specied
installation clearances
Never operate your Metro with the door ajar, except on
initial start up
Open the air control fully before opening the Metro’s door
WARNING! Important Information
• This appliance should be maintained & operated at all
times in accordance with this instruction manual
This appliance should not be operated with cracked door
glass, over worn, faulty or missing door seals
Do not use driftwood, treated or unseasoned (wet) fuel,
the use of most types of preservative treated wood as
fuel can be hazardous and will damage your appliance
• Burning unseasoned (wet) fuel or incorrect operation on
extended low burn cycles will cause excessive creosote
to form. Creosote is very corrosive and excessive
buildups will result in the ue pipe, ue spigot and upper
burn chamber failing. Failure of the applicance and/
or ue system due to creosote damage is not covered
under warranty. The formation of such is not an appliance
issue it is a fuel and operational issue
This appliance must be regularly maintained and
replacement parts must be authorised Metro parts only
Do not empty ash into a combustible container
Congratulations on the purchase of your Metro wood re