Metrohm 870 KF Titrino plus Specifications

General IconGeneral
BrandMetrohm
Model870 KF Titrino plus
CategoryLaboratory Equipment
LanguageEnglish

Summary

Introduction

1.1 Instrument description

Details the instrument's purpose and capabilities in Karl Fischer titration.

1.2 About the documentation

Explains symbols, conventions, and general notes on the manual.

1.3 Safety instructions

Provides essential safety guidelines for operating the instrument.

Overview of the instrument

Water determination according to Karl Fischer (KFT)

Installation

4.1 Setting up the instrument

Covers unpacking, checks, and optimal placement for the instrument.

4.2 Connecting a sensor

Instructions for connecting a polarizable electrode to the instrument.

4.3 Connecting a stirrer

Details on connecting compatible Metrohm stirrers.

4.4 Connecting a balance

Guidance on integrating a balance via RS-232/USB Box.

4.5 Connecting keyboard, printer and other USB devices

How to connect USB peripherals like keyboards, printers, and sticks.

4.6 Connecting instruments to the remote connector

Integrating the titrator into automation systems using a remote cable.

4.7 Attaching the exchange unit

Step-by-step instructions for physically attaching the exchange unit.

Operation

5.1 Switching the instrument on and off

Procedure for safely powering the instrument on and off.

5.2 Fundamentals of operation

Explains the keypad layout and dialog window structure.

5.3 Methods

Information on method templates, loading, saving, and exporting.

5.4 Sample data

Methods for entering sample identification and size.

5.5 Carrying out a determination

Comprehensive guide to performing a Karl Fischer titration.

5.6 Live modifications

How to edit sample data or parameters during a running determination.

5.7 Results

Viewing and interpreting the results of a titration.

5.8 Statistics

Displaying and analyzing statistical data from determination series.

5.9 Printing a report manually

Procedures for manually printing various types of reports.

5.10 Manual Control

Manually controlling functions like dosing and stirring.

System settings

6.1 Basic settings

Configuring fundamental instrument parameters like user and instrument names.

6.2 Managing solutions

Adding, editing, and deleting reagent solutions used in titrations.

6.3 File management

Managing methods and system data via USB, including import and backup.

6.4 Configuring external devices

Setting up printers, PC/LIMS reports, and keyboard layouts.

6.5 Instrument diagnosis

Loading software updates and performing diagnostic checks.

Parameters

7.1 Karl Fischer Titrations (KFT)

Detailed configuration of parameters specific to Karl Fischer titrations.

Handling and maintenance

8.1 Quality Management and validation with Metrohm

Information on Metrohm's quality systems, validation support, and maintenance.

Troubleshooting

9.1 Karl Fischer titration

Solutions for common problems encountered during Karl Fischer titrations.

9.2 Miscellaneous

Troubleshooting tips for other issues, including printer and USB device connectivity.

Appendix

10.1 Exchange unit

Details on the exchange unit, including dosing/filling rates and PREP parameters.

10.2 Stirring rate

How to adjust and calculate the stirring rate for optimal performance.

10.3 Balance

Information on how balances communicate sample size and unit data.

10.4 USB devices

Guidelines for connecting and using USB devices like keypads and keyboards.

10.5 System initialization

Procedure for re-initializing the instrument's internal file system.

10.6 Remote interface

Pin assignments and status diagrams for the remote interface.

10.7 Remote control via an RS-232 connection

Instructions for controlling the instrument remotely via an RS-232 connection.

Technical specifications

11.1 Measuring inputs

Specifications for the polarizer measuring inputs (Ipol and Upol).

11.2 Dosing drive

Technical details about the instrument's dosing drive.

11.3 Interfaces

Information on the instrument's USB, MSB, and remote interfaces.

11.4 Mains connection

Specifications for the power supply, including voltage and frequency.

11.5 Safety specification

Details on safety standards, design, testing, and instructions.

11.6 Electromagnetic compatibility (EMC)

EMC standards met for emission and immunity.

11.7 Ambient temperature

Operating, storage, and transport temperature ranges.

11.8 Reference conditions

Defines the ambient conditions for reference measurements.

11.9 Dimensions

Physical dimensions and weight specifications of the instrument.

Conformity and warranty

12.1 Declaration of Conformity

Statement certifying compliance with electrical and safety standards.

12.2 Quality Management Principles

Overview of Metrohm's quality management system and product development.

12.3 Warranty (guarantee)

Details on warranty terms, duration, and conditions.

Accessories

13.1 Scope of delivery

A list of items included with the 870 KF Titrino plus instrument.

13.2 Optional accessories

A list of optional accessories that can be purchased for the instrument.