Slurry Pump
WH22AAAAAA0EN_03B.DOC JAN 04-W08
Care and maintenance
2/3
9.6.3 The pump starts but the motor protection trips
Has flow path or pipe run been
modified ?
No
Yes
Alter the flow path or pipe run, or adjust the
rating of the drive motor and pump to suit
new operating conditions.
Is motor protection setting too low ?
No
Yes
Check against the motor rating plate and
adjust as necessary
Is shaft jammed or hard to turn?
No
Yes
Securely isolate the power supply.
Remove the belt guard and try to rotate the
pump shaft by hand.
Dismantle the pump and clean behind the
impeller. See section 9.5.2. Flush out the
pump and the pump sump
Dismantle the drive and check that both the
motor and pump shaft can be rotated. Fit
new bearings if necessary. See section 9.5
and the motor manufacturer’s instructions.
Check that pump clearances are correct.
See section 9.5.1.
9.6.4 The pump is running but the flow rate is too low or nil
Has operating conditions or pipe run
been modified ?
No
Yes
Alter the operating conditions, the pipe run,
or adjust the rating of the drive, motor and
pump to suit new operating conditions.
Has leakage been detected in plant ?
No
Yes
Renew or seal the leaking parts.