Slurry Pump
WH22AAAAAA0EN_03B.DOC JAN 04-W08
Care and maintenance
3/3
9.6.5 The pump runs unevenly or vibrates
Is the inlet flow uneven or is the pump
drawing air ?
No
Yes
Either adjust the feed to the pump, or adjust
the rating of the drive, motor and pump to
suit the operating conditions.
Are all valves open and are the pipes
clear ?
Yes
No
Remedy the fault.
Is the impeller clogged ?
No
Yes
Clean the impeller -see Dismantling and
Assembly, section 9.5.
9.6.6 Abnormal leakage from the shaft gland
See Shaft Seal Removal and Fitting, section 9.5.3.