External Power and External Trigger (“PWR/TRG”)
Signal
Trigger
Ground
Power
Hirose DF13A-3P-1.25H(51)
Hirose DF13-3S-1.25C
28AWG wire recommended
Pin 1 indicator (Δ) on DF13 family of connectors (DF13-3S-1.25C shown)
Power Input
Item
Value
Nominal Voltage
5.0 V DC
Input Voltage
Range
4.0V-15.8V DC
Average Power
3.5 Watts average, 8.0 W peak
(Camera Not Providing Power to
External GPS Module)
4.0 Watts average, 8.5 W peak
(Camera Providing Power to External
GPS Module)
The average power requirement of the RedEdge-MX integrated with a
DLS 2 is 4.0W. However, the camera can require instantaneous power of
up to 8.0W during operation for brief periods of time. Ensure the power