Product Install Guide – M4xx Series
03/11/22 | V1.9.9
12 Vdc on
multimeter**
It is important to dierentiate between the rst (accessories) stage and second (ignition) stage.
You have to make sure that you connect the ignition wire to a second (ignition) stage ignition feed. If
connected to the rst (accessories) stage the data recorded by the M4xx will be wrong, for example
idling.
The ignition feed must also be live when a Stop & Start occurs (engine o at trac lights). The feed
does not have to be live while cranking but it is good practice if it is.
Turn key to 1st stage*
Instrument Cluster O
0 Vdc on multimeter
0 Vdc on multimeter
12 Vdc on multimeter
Instrument Cluster On
Instrument Cluster On
Instrument Cluster O
Turn key to 2nd stage
Crank the engine
Stop the engine
**Sometimes the voltage will fall to 0Vdc while the engine is cranking and then returns to 12-14Vdc.
NOTE:
*Some vehicles do not have an accessories stage and the rst position of the barrel is ignition.
8. Ignition