Installation 15
_______________________________________________________________________________________________
_______________________________________________________________________________________________
MICROPLEX Operator’s Manual SOLID F40 Edition 1.1
!
- Avoid locating the printer close to an air current ( e.g. ventilators).
- The printer should not be exposed to direct sunlight.
- Do not touch the drum surface because the material is easy to
damage.
- Do not expose the printer to abrupt temperature changes.
- In order to run the printer reliably, please maintain the following
environmental conditions:
Temperature: +15°C to +30°C (59°F to 86°F) operating
-10°C to +35°C (14°F to 95°F) non-operating
Relative humidity: 30% to 80% operating
10% to 80% non-operating
Power standards
:
- Please connect the power plug to
230 V AC, 50 Hz (Europe, United Kingdom e.g.).
- The max. effective power input is appr. 3.7 kVA.
- The voltage support must not be impaired by interference.
- The printer is provided with a flexible 3x2.5 mm² connection cable
including a CEE plug 3x16. The corresponding CEE socket has to
be provided with a 16A fuse.
- If using an equivalent fixed connection ensure the grounding is
effected.
- Use the printer only within the allowable fluctuation range +
10%
of the power voltage.
Conditional connection for the SOLID F40
:
The maximum permissible system impedance Z
max
is appr. 0.02 Ohm.
The user of this device has to determine in consultation with the supply
authority, if necessary, that the equipment is connected only to a
supply of that impedance or less!
!
To avoid damage, the devices must be switched off (i.e. cut off
from the power supply) before the user begins connecting the
interface line.