7.4.2.10 P3 (Current overload protection) diagnosis and solution.
Error Code
P3
Malfunction conditions
If the outdoor current exceeds the current limit value, the LED
will display the failure.
Potential causes
Wiring mistake
Faulty over load protector
System block
Faulty outdoor PCB
Trouble shooting: