Atom B Series VRF 50/60Hz
32
Midea Atom B Series Engineering Data Book
Table 2-7.2: MDV-V36WDHN1(AtB) cooling capacity (continued)
Combination
(%) (Capacity
index)
Outdoor
temperature
(°C DB)
Indoor temperature(°C DB/WB)
DB:20.8,WB:14
DB:23.3,WB:16
DB:25.8,WB:18
DB:27,WB:19
DB:28.2,WB:20
DB:30.7,WB:22
DB:32,WB:24
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
50%
-5.0
3.5
0.4
4.0
0.5
4.5
0.7
5.0
0.9
5.4
1.0
5.7
1.0
6.1
1.0
-2.0
3.5
0.4
4.0
0.5
4.5
0.7
5.0
0.9
5.4
1.0
5.7
1.0
6.1
1.2
0.0
3.5
0.4
4.0
0.5
4.5
0.7
5.0
1.0
5.4
1.0
5.7
1.0
6.1
1.2
2.0
3.5
0.5
4.0
0.6
4.5
0.8
5.0
1.0
5.4
1.0
5.7
1.1
6.1
1.2
4.0
3.5
0.5
4.0
0.6
4.5
0.8
5.0
1.0
5.4
1.0
5.7
1.1
6.1
1.2
6.0
3.5
0.5
4.0
0.6
4.5
0.8
5.0
1.0
5.4
1.1
5.7
1.1
6.1
1.2
8.0
3.5
0.5
4.0
0.6
4.5
0.8
5.0
1.0
5.4
1.1
5.7
1.1
6.1
1.2
10.0
3.5
0.5
4.0
0.6
4.5
0.8
5.0
1.0
5.4
1.1
5.7
1.1
6.1
1.2
12.0
3.5
0.5
4.0
0.6
4.5
0.8
5.0
1.0
5.4
1.1
5.7
1.1
6.1
1.3
14.0
3.5
0.5
4.0
0.6
4.5
0.8
5.0
1.0
5.4
1.1
5.7
1.1
6.1
1.3
16.0
3.5
0.5
4.0
0.6
4.5
0.8
5.0
1.0
5.4
1.1
5.7
1.1
6.1
1.3
18.0
3.5
0.5
4.0
0.6
4.5
0.8
5.0
1.1
5.4
1.1
5.7
1.1
6.1
1.3
20.0
3.5
0.5
4.0
0.6
4.5
0.8
5.0
1.1
5.4
1.1
5.7
1.1
6.1
1.3
21.0
3.5
0.5
4.0
0.6
4.5
0.8
5.0
1.1
5.4
1.1
5.7
1.1
6.1
1.3
23.0
3.5
0.5
4.0
0.6
4.5
0.9
5.0
1.1
5.4
1.2
5.7
1.2
6.1
1.3
25.0
3.5
0.5
4.0
0.6
4.5
0.9
5.0
1.1
5.4
1.2
5.7
1.2
6.1
1.4
27.0
3.5
0.5
4.0
0.6
4.5
0.9
5.0
1.1
5.4
1.2
5.7
1.2
6.1
1.4
29.0
3.5
0.6
4.0
0.7
4.5
0.9
5.0
1.2
5.4
1.2
5.7
1.3
6.1
1.4
31.0
3.5
0.6
4.0
0.7
4.5
1.0
5.0
1.2
5.4
1.3
5.7
1.3
6.1
1.5
33.0
3.5
0.6
4.0
0.7
4.5
1.0
5.0
1.3
5.4
1.4
5.7
1.4
6.1
1.6
35.0
3.5
0.6
4.0
0.8
4.5
1.1
5.0
1.4
5.4
1.4
5.7
1.5
6.1
1.7
37.0
3.2
0.7
3.7
0.8
4.2
1.1
4.6
1.4
5.0
1.5
5.2
1.5
5.6
1.8
39.0
3.1
0.7
3.6
0.8
4.0
1.2
4.5
1.4
4.8
1.6
5.0
1.6
5.4
1.8
41.0
2.9
0.7
3.4
0.9
3.8
1.2
4.2
1.4
4.5
1.6
4.8
1.7
5.1
1.9
43.0
3.0
0.8
3.4
0.9
3.8
1.3
4.2
1.4
4.5
1.7
4.8
1.7
5.1
2.0
46.0
2.8
0.8
3.2
0.9
3.5
1.3
3.9
1.4
4.2
1.8
4.5
1.8
4.8
2.1
48.0
2.6
0.8
3.0
1.0
3.4
1.4
3.7
1.5
4.0
1.8
4.2
1.9
4.5
2.2
50.0
2.2
0.7
2.5
0.9
2.8
1.2
3.1
1.4
3.4
1.7
3.6
1.7
3.8
2.0
52.0
1.8
0.7
2.1
0.8
2.3
1.2
2.6
1.3
2.8
1.5
2.9
1.6
3.1
1.8
54.0
1.7
0.6
1.9
0.7
2.1
1.0
2.4
1.1
2.6
1.4
2.7
1.4
2.9
1.6
Abbreviations:
CR: Combination ratio
TC: Total capacity (kW)
PI: Power input (compressor + outdoor fan motor) (kW)
Notes:
1. Shaded cells indicate rating condition.