Condition of ending defrosting:
If any one of the following items is satisfied, the defrosting will terminate and the machine will turn to
normal heating mode.
(1) The defrosting time is reached to the setting value.
(2) The defrosting has been running for 3 minutes and T2≥TCDE1℃.
(3) The defrosting has been running for 2 minutes, check the value of T2. If T2
-T2min≥TCDE2℃
during 4 minutes, the defrosting will terminate.
For MSMAD-24HRN1-QB8W models:
AC will enter the defrosting mode according to the value of temp. of T3 and the value range of temp.
change of T3 and also the compressor running time.
During the defrosting mode, the compressor keep running, indoor and outdoor motor will stop, defrost
lamp of the indoor unit will be lighted .“ .” Will be displayed.
Condition of ending defrosting:
If any one of the following items is satisfied, the defrosting will terminate and the machine will turn to
normal heating mode.
(1) T3 rises to be higher than TC2.
(2) The machine has run for 10 minutes in defrosting.
10.4.3.5 High evaporator coil temp.T2 protection:
Compressor off
Outdoor fan motor off
Compressor and outdoor
fan motor on
Compressor and outdoor
fan motor off
Compressor and outdoor
fan motor on
8.4.4 Auto-mode
This mode can be chosen with remote controller.
In auto mode, the machine will choose operation mode according to ∆T (∆T =T1-Ts).
T1-Ts
Cooling
Heating*
Fan only
Heating*: For cooling only models, they will run at fan speed
AC will run in auto mode in the below cases:
(1) Pressing the forced auto button.